Technical data
Network OS Message Reference 125
53-1002489-01
Chapter
26
PORT System Messages
PORT-1003
Message <timestamp>, [PORT-1003], <sequence-number>,, WARNING, <switch-name>, Port <port
number> Faulted because of many Link Failures.
Probable Cause Indicates that the specified port is disabled because of multiple link failures on the port that has
exceeded the threshold internally set on the port. This problem is related to the hardware.
Recommended
Action
Check and replace (if necessary) the hardware attached to both the ends of the specified port,
including:
• The small form-factor pluggable (SFP)
• The cable (fiber optic or copper inter-switch link (ISL))
• The attached devices
After checking the hardware, execute the no shutdown command to re-enable the port.
Severity WARNING
PORT-1004
Message <timestamp>, [PORT-1004], <sequence-number>,, INFO, <switch-name>, Port <port
number> (0x<port number (hex)>) could not be enabled because it is disabled due to
long distance.
Probable Cause Indicates that the specified port cannot be enabled because other ports in the same group have
used the buffers of this port group. This happens when other ports are configured to be long
distance.
Recommended
Action
To enable the specified port, perform one of the following actions:
• Reconfigure the other E_Ports so that they are not long distance.
• Change the other E_Ports so that they are not E_Ports.
This will free some buffers and allow the port to be enabled.
Severity INFO
PORT-1011
Message <timestamp>, [PORT-1011], <sequence-number>,, INFO, <switch-name>, An SFP for
interface Fibre Channel <rbridge-id number>/<slot number>/<port number> is
removed.
Probable Cause Indicates that an SFP has been removed from the specified port.