Technical data
124 Network OS Message Reference
53-1002489-01
PLAT-1007
25
PLAT-1007
Message <timestamp>, [PLAT-1007], <sequence-number>,, ERROR, <switch-name>, Turning off
Fan <Fan Number> because of airflow direction <Global airflow direction>.
Probable Cause Indicates that the fan is turned off because of the wrong airflow direction.
Recommended
Action
Replace the fan FRUs with airflow in the same direction.
Severity ERROR
PLAT-1008
Message <timestamp>, [PLAT-1008], <sequence-number>,, ERROR, <switch-name>, Unable to
read EEPROM for Global airflow direction.
Probable Cause Indicates a failure to read the EEPROM.
Recommended
Action
Inform the factory about the error.
Severity ERROR
PLAT-1009
Message <timestamp>, [PLAT-1009], <sequence-number>,, ERROR, <switch-name>, Unable to
read EEPROM Valid Signature for Global airflow direction.
Probable Cause Indicates a failure to read the EEPROM.
Recommended
Action
Inform the factory about the error.
Severity ERROR