PLAT-1004
Message <timestamp>, [PLAT-1004], <sequence-number>, FFDC, CRITICAL, <switch-name>,
Turning off Fan <Fan Number> because of airflow direction mismatch.
Probable Cause Indicates that the fan field-replaceable unit (FRU) is turned off because of wrong airflow direction.
Recommended
Action
Replace the fan FRU.
Severity CRITICAL
PLAT-1005
Message <timestamp>, [PLAT-1005], <sequence-number>, FFDC, CRITICAL, <switch-name>,
Unable to read EEPROM for Global airflow direction. Setting to default Port side
intake.
Probable Cause Indicates a failure to read the EEPROM.
Recommended
Action
Inform the factory about the error.
Severity CRITICAL
PLAT-1006
Message <timestamp>, [PLAT-1006], <sequence-number>,, CRITICAL, <switch-name>, Unable to
read EEPROM for Global airflow direction. Shutting off Fans now.
Probable Cause Indicates a failure to read the EEPROM. The fans will be shut down.
Recommended
Action
Inform the factory about the error.
Severity CRITICAL