Technical data
106 Network OS Message Reference
53-1002489-01
NSM-1024
22
Recommended
Action
No action is required.
Severity INFO
NSM-1024
Message <timestamp>, [NSM-1024], <sequence-number>,, INFO, <switch-name>, rBridge ID
<DomainId> has left Port-channel <PortChannelKey>. Port-channel is a vLAG with
rBridge IDs<RbridgeList>.
Probable Cause Indicates that an rBridge has left the vLAG.
Recommended
Action
No action is required.
Severity INFO
NSM-1025
Message <timestamp>, [NSM-1025], <sequence-number>,, INFO, <switch-name>, rBridge ID
<DomainId> has left Port-channel <PortChannelKey>. Port-channel has only rBridge
ID <RbridgeList> and is no longer a vLAG.
Probable Cause Indicates that the vLAG no longer exists.
Recommended
Action
No action is required.
Severity INFO
NSM-1026
Message <timestamp>, [NSM-1026], <sequence-number>,, INFO, <switch-name>, SFP for
interface <InterfaceName> is inserted.
Probable Cause Indicates that a small form-factor pluggable (SFP) has been inserted in an interface.
Recommended
Action
No action is required.
Severity INFO
NSM-1027
Message <timestamp>, [NSM-1027], <sequence-number>,, INFO, <switch-name>, SFP for
interface <InterfaceName> is removed.
Probable Cause Indicates that an SFP has been removed from an interface.