Technical data
90 Network OS Message Reference
53-1002489-01
L2SS-1005
18
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
L2SS-1005
Message <timestamp>, [L2SS-1005], <sequence-number>,, ERROR, <switch-name>,
MAC-address-table hash failed even after two attempts for slot <slot> chip <chip>.
Probable Cause Indicates that the Media Access Control (MAC) address table hash failed even after two hash
changes on the specified chip.
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
L2SS-1006
Message <timestamp>, [L2SS-1006], <sequence-number>,, INFO, <switch-name>,
MAC-address-table is 95 percent full.
Probable Cause Indicates that the MAC address table on the chip is 95 percent (%) full.
Recommended
Action
Clear some of the entries using the no mac-address-table static MAC address command or wait
until the old entries age out.
Severity INFO
L2SS-1007
Message <timestamp>, [L2SS-1007], <sequence-number>,, INFO, <switch-name>,
MAC-address-table on slot <Slot_id> chip <Chip_id> is less than 90 percent full.
Probable Cause Indicates that the MAC address table on the specified chip is less than 90 percent (%) full.
Recommended
Action
No action is required. The l2sys starts learning the entries.
Severity INFO
L2SS-1008
Message <timestamp>, [L2SS-1008], <sequence-number>,, INFO, <switch-name>, Fabric-wide
Layer 2 flush command issued.
Probable Cause Indicates that the clear fabric-mac vlan command is executed. The entire Layer 2 forwarding table
will be cleared.