Technical data

Network OS Message Reference 75
53-1002489-01
FW-1435
12
Recommended
Action
Replace the faulty or deteriorating fan field-replaceable units (FRUs).
Severity WARNING
FW-1435
Message <timestamp>, [FW-1435], <sequence-number>,, WARNING, <switch-name>, Switch status
change contributing factor Flash: usage out of range.
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the flash usage is out of
range. The policy was set using the system-monitor command.
Recommended
Action
Run the clear support command to clear the kernel flash.
Severity WARNING
FW-1439
Message <timestamp>, [FW-1439], <sequence-number>,, WARNING, <switch-name>, Switch status
change contributing factor Switch offline.
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the switch is offline.
Recommended
Action
Run the chassis enable command.
Severity WARNING
FW-1440
Message <timestamp>, [FW-1440], <sequence-number>,, INFO, <switch-name>, <FRU label>
state has changed to <FRU state>.
Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to absent.
Recommended
Action
Verify that the event was planned.
Severity INFO
FW-1441
Message <timestamp>, [FW-1441], <sequence-number>,, INFO, <switch-name>, <FRU label>
state has changed to <FRU state>.
Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to inserted. This
means that an FRU is inserted but not powered on.