Technical data
Network OS Message Reference 73
53-1002489-01
FW-1425
12
Recommended
Action
Run the show system monitor command to determine the policy violation.
Severity WARNING
FW-1425
Message <timestamp>, [FW-1425], <sequence-number>,, INFO, <switch-name>, Switch status
changed from <Bad state> to HEALTHY.
Probable Cause Indicates that the switch status has changed to a healthy state. This occurred because a policy is
no longer violated.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1426
Message <timestamp>, [FW-1426], <sequence-number>,, WARNING, <switch-name>, Switch status
change contributing factor Power supply: <Number Bad> bad, <Number Missing>
absent.
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty or
missing power supplies is greater than or equal to the policy set by the system-monitor command.
Recommended
Action
Replace the faulty or missing power supply.
Severity WARNING
FW-1427
Message <timestamp>, [FW-1427], <sequence-number>,, WARNING, <switch-name>, Switch status
change contributing factor Power supply: <Number Bad> bad.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty power supplies is greater than or equal to the policy set by the system-monitor command.
Recommended
Action
Replace the faulty power supply.
Severity WARNING