User manual

18DCA Intertel DCA Intertel
DCA Intertel 19 DCA Intertel
Please note: the parameters marked with the symbol D represent the default
values.
(8) Note
If the Interface parameter is set in infrared and ow control is required, any
time a transmission is effected a time break of one time and a half the byte
transmission is needed (for example 1.5 msec at 9600 bps). The reason is for
Half Duplex type of infrared line communication. As a result the Busy condition
check must be waited when transmitting data to the printer.
If said condition would slow down print-out, it is alternatively possible to trans-
mit the bytes to be printed in xed length blocks (for example 16 bytes at a
time) and to wait for the necessary time to receive a likely XON/XOFF.
(9) Note
The “IR Protocol” parameter is visualizzato only if interface is set in”Infrared”.
(10) Note
It is not possible to modify the “ow control” parameter if interface is set in in-
frared because it is automatically set in XON/XOFF.
(11) Note
This parameter regulates battery recharge time. If set to Alkaline, battery re-
charge is disabled. If another type of battery other than those supplied with the
printer is used, select the closest appropriate charge value from the list.
(12) Note
This parameter regulates the period of inactivity after which the printer shuts
off automatically to avoid battery discharge. Each time the key is pressed quik-
kly, the parameter will change and the current value will be printed out. Once
the desired value has been attained, hold the key down for at least a second
to pass to the next parameter, and so on. Printing out of a new printer set up
report indicates that set up is complete.