SC 32 / SC 64 Digital Matrix Processors Installation Guide
IMPORTANT SAFETY INFORMATION WARNING FOR YOUR PROTECTION READ THE FOLLOWING: KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS The symbols shown above are internationally accepted symbols that warn of potential hazards with electrical products. The lightning flash with arrowpoint in an equilateral triangle means that there are dangerous voltages present within the unit.
IMPORTANT SAFETY INFORMATION DECLARATION OF CONFORMITY ELECTROMAGNETIC COMPATIBILITY This device complies with part 15 of the FCC Rules and the Product Specifications noted on the Declaration of Conformity. Operation is subject to the following two conditions: • t his device may not cause harmful interference, and • this device must accept any interference received, including interference that may cause undesired operation.
Table of Contents SC 32 / SC 64 Section 1 - Introduction......................... 1 1.1 Defining the SC 32 / SC 64.............. 1 1.2 Service Contact Info........................ 2 1.3 Warranty........................................ 3 Section 2 - Getting Started...................... 4 2.1 Front Panel.................................... 4 2.2 Rear Panel .................................... 6 Section 3 - Wiring.................................. 8 3.1 SC 32 and SC 64 Wiring................... 8 3.
SC 32 / SC 64 Introduction Section 1 Section 1 - Introduction Based on the principles of the dbx Zone Processing products, the SC 32 / SC 64 Digital Matrix Processors are the new flagship products for Digital Matrix Processing. Wizard driven configuration using HiQnet System Architect™ makes unprecedented DSP power, incredible routing flexibility and a rich palette of processing tools accessible with the minimum of training.
Section 1 Introduction SC 32 / SC 64 1.2 Service Contact Info If you require technical support, contact dbx Technical Support. Be prepared to accurately describe the problem. Know the serial number of your device - this is printed on a sticker attached to the chassis. If you have not already taken the time to fill out your warranty registration card and send it in, please do so now. You may also register online at www. dbxpro.com.
SC 32 / SC 64 Introduction Section 1 1.3 Warranty This warranty is valid only for the original purchaser and only in the United States. 1. The warranty registration card that accompanies this product must be mailed within 30 days after purchase date to validate this warranty. You can also register online at www.dbxpro.com. Proof-of-purchase is considered to be the responsibility of the consumer. A copy of the original purchase receipt must be provided for any warranty service. 2.
Section 2 SC 32 / SC 64 Getting Started Section 2 - Getting Started 2.1 Front Panel SC 32 SIGNAL SC 64 SIGNAL SIGNAL FRONT PANEL LED DISPLAY Information relating to network configuration, current time and date, HiQnet™ Node Address, SC firmware version and device status. PAGE SELECT BUTTONS Allow front panel navigation. RS-232 LED RS-232 connection indication. CLIP LED Global DSP clip indication. LINK/ACT LED Link/Activity indication.
SC 32 / SC 64 Getting Started Section 2 POWER LED Power present indication. CARD POSITION LABELS - I/0 CARD TYPE INDICATION LEDS Analog or digital, input or output indication per card position. Illuminate as shown below: IN (Green) OUT (Orange) D-IN (Blue) D-OUT DESCRIPTION (Yellow) X 8 channels are analog in. X X Future feature. X 8 channels are analog out. X X Future feature. X Future feature. X Future feature.
Section 2 SC 32 / SC 64 Getting Started 2.2 Rear Panel SC 32 A HARMAN INTERNATIONAL COMPANY SALT LAKE CITY , UTAH SC 32 ATTENTION: RISQUE DE CHOC IEC60065 ELECTRIQUE - NE PAS OUVRIR FUSE REPLACEMENT RATINGS 100V-240V T 2.
SC 32 / SC 64 Getting Started Section 2 OPTO Opto-isolator conducts when device is powered and functioning correctly. LOGIC OUTPUTS Allow SC 32 / SC 64 to control up to six LEDs or relays. ETHERNET CONNECTORS Ethernet connectors for SC 32 / SC 64 configuration, control and monitoring. Also used for integration with third party control systems using IP control (Integrated Ethernet switch allows daisy-chaining of devices within a rack).
Section 3 Wiring SC 32 / SC 64 Section 3 - Wiring 3.1 SC 32 and SC 64 Wiring Audio Cable Wiring All audio and control connections to the SC 64/32 are via 12 terminal female Phoenix Combicon-style 3.5mm connectors, which are supplied for making these connections.
SC 32 / SC 64 Wiring Section 3 OPTO Output In addition to the six standard logic outputs, there is an isolated output, which fails safe (open circuit) if the unit becomes faulty. +supply RELAY CONTROL INPUTS C C 1 2 3 4 5 6 7 8 R R OPTO NO C NC + LOGIC OUTPUTS - C 1 2 3 4 5 6 ground OPTO Output Logic Outputs Used to connect ‘tally’ indicator LED’s or relays.
Section 3 SC 32 / SC 64 Wiring 3.2 Zone Controller Wiring and Installation Zone Controller Wiring All Zone Controllers can be wired serially or in parallel. To wire in series, each Zone Controller must have an identification number (ID) chosen using the DIP switches on the side of the controller (see diagram A). A single Zone Controller can be used to control multiple outputs.
SC 32 / SC 64 Wiring Section 3 ZC-1 - The ZC-1 is a programmable zone controller that allows input or output volume level control from a wall panel. ZC-2 - The ZC-2 is a programmable zone controller that allows input or output volume level and mute control from a wall panel. ZC-3 - The ZC-3 allows wall panel routing and Actions selection for the SC devices. ZC-4 - The ZC-4 provides contact closure routing and Actions selection for room combining or fire safety applications.
Section 3 SC 32 / SC 64 Wiring Diagram A Diagram B 80-1342-A H UL-6500 UL-6500 80-1342-A ID# 4 IEC60065 IEC60065 RJ45 ELECTRIQUE - NE PAS OUVRIR WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE FUSE REPLACEMENT RATINGS T 2.5A, H 250V CONNECT ONLY TO ZONE CONTROLLER INPUT . RJ45 ATTENTION: RISQUE DE CHOC IEC60065 SC 64 100V-240V CONNECT ONLY TO ZONE CONTROLLER INPUT .
SC 32 / SC 64 Section 3 Wiring Cable Specification: EIA/TIA 568A Standard (pin to pin) 24 AWG wire RJ-45 (8-Position) RJ-45 (8-Position) 1 White/Green 2 Green White/Orange Blue White/Blue Orange White/Brown Brown 3 4 5 6 7 8 1 -VREF 2 -Dip 1 3 -Dip 2 4 -Dip 3 5 -Dip 4 6 -Dip 5 7 -Dip 6 8 -GND Diagram A H D OPTION SLOT 2 ATTENTION: SC 64 8 100V-240V T 2.
Section 3 SC 32 / SC 64 Wiring SC 32 / 64.
SC 32 / SC 64 Technical Specifications Section 4 Section 4 - Technical Specifications FRONT PANEL INDICATORS Per channel: Per 8 channel bank: Other: ANALOG INPUTS Connectors: Channels: Line/Mic Inputs: Type: Input Impedance: Maximum Input Level: Noise Floor: Dynamic Range: CMRR: EIN: Phantom Power: A/D Latency: ANALOG OUTPUTS Connectors: Channels: Type: Impedance: Maximum Output Level: Noise Floor: Dynamic Range: D/A Latency: SYSTEM PERFORMANCE Dynamic Range: Frequency Response: THD+N: Inter-channel cros
Section 4 SC 32 / SC 64 Technical Specifications ZONE CONTROLLER INPUTS Connectors: Number: Useage: RJ-45 2 connectors with 6 channels per connector for a total of 12 inputs For use with dbx ZC wall controllers LOGIC OUTPUTS Connector: Number: Logic Output Voltage: Logic Output Impedance: Logic Output Current: Phoenix/Combicon, 3.5mm pitch 6 0 or +5 V unloaded 440 Ω 10 mA source, 60 mA sink RELAY CONTACT CLOSURE Connector: Contacts: Contact Rated Load: Phoenix/Combicon, 3.