User manual
得伯乐科技有限公司
DBL Technology Limited GoIP User Manual
Web: www.dbltek.com
Tel: +86 755 8829 0211
3.4.2 PC Port Setting
The PC port can be set to connect other network equipment through the route or bridging
mode. The two setting modes are as follows:
A. Bridging
When the PC port is set to the bridging mode, the relation between the LAN port and the PC port
is layer 2 switching. The network equipment connected with the PC port same as the connection with
the LAN port.
B. Fixed IP Address
Select the fixed IP, and the following setting parameters are displayed. Enter the IP address and
subnet mask (the network section of the IP address should be different from that of the LAN port to
prevent conflict).
C. Enable the DHCP Service
This service can be enabled only when the PC port of the GoIP is set as the fixed IP. To enable
the DHCP service, you need to enter the start address and end address.
E. Advance…
Click Advance, and the Hardware address and Broadcast address are displayed in the page.
The hardware address is used to enter the MAC address in the format of XX: XX: XX: XX: XX:
XX.
The broadcast address is used to communicate with other computers that are connected to the
ATA.