VII. Call settings
i. Call Logic :
RoIP can be connected between each other by SIP server as a proxy,can also be used
independently by the way point to point.Because communication through the server will reduce
efficiency and increase instability,it is strongly recommended to use the way point to point
network.Therefore,this guide focuses on telling point is configured.
ii. Log in and call logic
Between the different RoIP102 need to know each others IP and the attribution,so you need to
login.In the case of using the SIP server mode,all terminals connected in network must be log in to
the SIP server,Phone number is allocated by the SIP server.
When using point to point connection,any RoIP102 as a Host to other terminal login,and the
host itself need to log into owns IP address.Host set up owns phone number to be called by another
terminal.The terminal need to log in to the host must have to set themselves phone number for
identification.
iii. Call Settings
Group 1 : is to set the group number.Each RoIP1102 need to set a number.
Group SIP Number : is connected to the PPT group and the groups unique idendifier,if using a
SIP server provided by the server end.If use of point to point connections from their own layout
manager.
SIP Proxy : is the SIP service address.When using point to point connection,if RoIP102 as a
host,you need to fill out itselves IP address or DDNS address.If as a terminal,fill the host should be
log in whos IP address or DDNS address.
Auto Dial Number : is a appropriate number in the terminal it self to call the host automatically.