CONNECTING OUTPUTS BETWEEN MULTIPLE MODULES (power supply linking)
POWER SUPPLY LINK
English
NOTE FOR THE INSTALLER (100-120V). The nameplate data on the speaker panel refer to (and are
limited to) the cable provided. If you do not use the supplied cable, the maximum allowed limits of
currents (and powers) of LINK are indicated in the following table:
Model Current (100-120 V) Powers (100-120 V)
IG4T (100-120 V) 14 A 1600 W
The cables must be properly sized and design, installation and system testing should be performed
exclusively by qualied personnel. A.E.B. Industriale accepts no responsibility in case of use of
cables which are unsuitable, non-certied, non-compatible with the correct system sizing and the
regulations in force in the country of use.