Manual
11
EnglishEnglishEnglish
user manualuser manual
EnglishEnglishEnglish
user manualuser manual
12
1
2
4 3 5 6
8
9
7
10
17
11
12
16
15
14
13
18
19
19
TECHNICAL SPECIFICATION
System Active 2-Amps
Type of amplifier Digital - Class D (DIGIPRO G2 technology)
RMS power 3000W (1500 W + 1500 W )
Musical power 6000W
Frequency response (+/-3dB) 30-120Hz
Crossover LF-MF (Low-Mid) 75 - 120Hz (5Hz steps) selectable
Sound pressure (SPL) 141dB peak
Component parts 2 woofer 18" -RCF 4"
coil
Input sensitivity nominal 0dBu
Input impendence Balanced 20Kohm
Unbalanced 10Kohm
Power supply Full range 115Vac -230Vac, 50-60Hz con PFC
Inrush Current 32,96 A
DSP Analog Device 56 bits
Audio conversion 24 bit / 96kHz
Volume control Digital
Box material Birch plywood, black painted orange peel
Housing shape Rectangular
Handle 4 x side
Front grille Performed sheet 1.5mm with internal foam
Dimension (WxHxD) 1100x720x580mm
Weight 75Kg (neodimium cones) 83Kg (ceramic cones)
Input
Link
Ready
Limiter
Signal
Mute/Prot
Input
Link
Service
Data
USB
Remote
Preset
Active
Link
Active
0dB
+4dB
Audio Balanced Input/Link
Input Control
RDNET
SUB Phase/Delay
Input Sens
Status
75
80
85
90
95
100
105
110
115
120
Xover Out
Xover Frequency
selection 24dB/oct
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
Phase
mSec
DSP Up-grade
Hz
30
4.5
0°
180°
Delay
O
N
F
F
O
ACTIVE P.F.C.
Digital Vertical Array
S
Made in Italy
Xover Frequency
selection 24dB/oct
NEODYMIUM
CERAMIC
FULL RANGE MAINS INPUT
115-230V~ 50-60Hz
20A (115V~)
10A (230V~)
MODULE LED LED LED LED
STATUS «READY» «MUTE/PROT» «SIGNAL» «LIMIT»
Power ON OFF ON for 5 sec. OFF OFF
Normal use ON OFF
Partial fault ON
Total fault OFF ON OFF
Amplifier temperature management:
First thermal ON
threshold The amplifier module begins a gradual
decrease of the volume in 0.1dBm steps to
compensate 'temperature increase up to a
maximum reduction of 3dBm.
Second thermal ON Audio ACTIVE
threshold The amplifier module reduces the volume further 3dBm
always in 0.1dBm steps up to a maximum reduction of
6dBm respect original volume.
NB The temperatures shown on the plug-in RDnet software refer to the internal temperature of the power semiconductors.
These temperatures are not displayed the temperatures of accessible parts user
MODULE FUNCTIONS
Audio MUTED
Initialization of the amplifier module
Normal operation Normal operation Audio ACTIVE
Module initialization complete and correct
Cyclic flashing Normal operation Normal operation Audio ACTIVE
(3 or more quick flashes) The module has detected a partial anomaly
and remains active with limited functions
Cyclic flashing Audio MUTED
The module has detected a serious anomaly
and is in protected mode
Cyclic flashing Normal operation Normal operation Audio ACTIVE
(1 slow flashes)
Cyclic flashing Normal operation Normal operation
(2 quick flashes)
DIAGNOSTICS TABLE
MODULE STATUS LED LED LED MODULE FUNCTIONS
« » « » «ACTIVE»
RDNET not active OFF OFF OFF
RDNET connect ON ON
OFF OFF
Remote Preset Active LINK
The module is functioning normally.
The volume (INPUT SENS) and the rotary switch (DSP Preset)
are active
Cyclic flashing The amplifier module is remotely controlled by RDNET.
The volume (INPUT SENS) and the rotary switch (DSP Preset)
are bypassed
Equalization «USER Eq» Cyclic flashing The module functions normally.
(rotary switch The equalization saved by means of RDNET is being used.
«DSP Preset» set to 9)