EMI CLASSIFICATION
According to the standards EN 55103 this equipment is designed and suitable to operate in E3
(or lower E2, E1) Electromagnetic environments.
TECHNICAL SPECIFICATION
System Active
Type of amplifier Digital - Class (DIGIPRO G2 technology)
RMS power 1500W
Musical power 3000W
Frequency response +/-3dB 30-110Hz
Crossover LF-MF (Low-Mid) 60-105Hz (step 5Hz) selected
Sound pressure (SPL) 139dB max
Component parts 1 woofer 21" - VC 4,5”
Input sensitivity nominal 0dBu
Input impendence
Balanced 20Kohm
Unbalanced 10Kohm
Power supply Full range 115Vac -
Inrush current 16,1A
DSP Analog Device 56 bits
Audio conversion 24 bit / 96kHz S/N=116dB
Volume control Digital
Box material Birch plywood
Housing shape Rectangular
Colour Black
Handle 3 x side (metal)
Rear grille Performed sheet 1.5mm with internal foam
Dimension (WxHxD) 580x800x720mm
Weight 52,5Kg (neodymium woofer)
56,5Kg (ceramic woofer)
230Vac, 50-60Hz con PFC
user manualuser manual
EnglishEnglishEnglish
11
1
2
4
3
5
6
8
9
7
10
17
11
12
16
15
14
13
20
20
18
Input
Link
Ready
Limiter
Signal
Mute/Prot
Data
Input
Data
Link
Service
Data
USB
Remote
Preset
Active
Link
Active
BB
dd
TECHNOLOGIESTECHNOLOGIES
0dB
+4dB
Audio Balanced Input/Link
Input Control
SUB Phase/Delay
Input Sens
Status
60
65
70
75
80
85
90
95
100
105
Xover Out
Xover Frequency
selection 24dB/oct
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
Phase
mSec
DSP Up-grade
Hz
4.5
180°
Delay
Digital Vertical Array
NEODYMIUM
CERAMIC
S
11
55
22
11
O
N
F
F
O
FULL RANGE MAINS INPUT
115-230V~ 50-60Hz
10A (115V~)
5A (230V~)
ACTIVE P.F.C.
O
N
F
F
O
LINK
230V~ (15A max) 3450Wmax
115V~ (10A max) 1150Wmax
G2G2
19
MODULE LED LED LED LED
STATUS «READY» «MUTE/PROT» «SIGNAL» «LIMIT»
Power ON OFF ON for 5 sec. OFF OFF
Normal use ON OFF
Partial fault ON
Total fault OFF ON OFF
Amplifier temperature management:
First thermal ON
threshold The amplifier module begins a gradual
decrease of the volume in 0.1dBm steps to
compensate 'temperature increase up to a
maximum reduction of 3dBm.
Second thermal ON Audio ACTIVE
threshold The amplifier module reduces the volume further 3dBm
always in 0.1dBm steps up to a maximum reduction of
6dBm respect original volume.
NB The temperatures shown on the plug-in RDnet software refer to the internal temperature of the power semiconductors.
These temperatures are not displayed the temperatures of accessible parts user
MODULE FUNCTIONS
Audio MUTED
Initialization of the amplifier module
Normal operation Normal operation Audio ACTIVE
Module initialization complete and correct
Cyclic flashing Normal operation Normal operation Audio ACTIVE
(3 or more quick flashes) The module has detected a partial anomaly
and remains active with limited functions
Cyclic flashing Audio MUTED
The module has detected a serious anomaly
and is in protected mode
Cyclic flashing Normal operation Normal operation Audio ACTIVE
(1 slow flashes)
Cyclic flashing Normal operation Normal operation
(2 quick flashes)
DIAGNOSTICS TABLE
MODULE STATUS LED LED LED MODULE FUNCTIONS
« » « » «ACTIVE»
RDNET not active OFF OFF OFF
RDNET connect ON ON
OFF OFF
Remote Preset Active LINK
The module is functioning normally.
The volume (INPUT SENS) and the rotary switch (DSP Preset)
are active
Cyclic flashing The amplifier module is remotely controlled by RDNET.
The volume (INPUT SENS) and the rotary switch (DSP Preset)
are bypassed
Equalization «USER Eq» Cyclic flashing The module functions normally.
(rotary switch The equalization saved by means of RDNET is being used.
«DSP Preset» set to 9)