User Manual
LVX Professional Active Speaker 
11
ENGLISH
3.  CHARACTERISTICS AND PROTECTION 
Front Grille 
The speakers’s components in the box are protected by 1,2mm  (LVX 8  and LVX 10) or 1,5mm 
(LVX 12 and LVX 15) metal steel grille covered by foam on backside. 
Cooling 
Thermal control is provided  by  the internal  microprocessor which, by  means of  two sensors, 
controls the temperature of the amplifier and of the power supply, avoiding overheating by limiting 
the overall volume. 
In  case  of  overheating  (>  80  degrees)  the  volume  decreases  proportionally  to  the  temperature 
increase, making the change unnoticeable. 
The correct volume and  all  the  functions are  automatically restored when standard  operating 
temperatures are reached. 
Switch on 
The amplifiers are equipped with a microprocessor to control the DSP and the amplifier. 
The  correct switch  on  of  the  amplifier  is  ensured  by  an  initialization  procedure;  during  this  test 
stage and the LEDs (“Limiter”, “Signal” and “Ready”), located on the amplifier module, remain off 
for approx. 2 sec. 
At the  end of  the switch on procedure, the front LED lights up (if enabled) and on the amplifier 
module the “Ready” green LED only remains steadily on. 
In case of severe failure of the speaker, the LED on the front panel flashes several times and on 
the amplifier module, the “Limiter” red LED flashes and the speaker switches to “mute”. 
Failure indications and safeties 
The microprocessor is able to signal three different kinds of failure by flashing the “Limiter” red LED 
on the amplifier panel before the lighting up of the “Ready” green LED. The three types of failure 
are: 
-  WARNING:  a  non-severe  error  or  auto-ripristinate malfunction is  detected  and  the 
performance of the speaker is not limited 
-  LIMITATION:  an  error is  detected  and the  performance  of the  speaker  is limited  (the 
sound level is reduced by 3dB). 
-  This does not affect the operation of the speaker since it continues to operate. However, 
it is necessary to call the service center to solve the issue. 
-  FAILURE: a severe malfunction is detected. The speaker switches to “mute”. 
Flashing
Indication
1 or 2
Warning
3 or 4
Limitation
from 5 to 8
Failure
In case of failure, the “Ready” green LED remains off. 
Perform the checks listed below: 
-  Check if the speaker is properly connected to the power supply. 
-  Make sure that the power supply is of correct voltage. 
-  Check that the amplifier is not overheated. 
-  Disconnect the speaker from the mains power supply, wait for a few minutes and 
connect it again. 
If after these tests the red “LIMITER” LED is still on, please contact an authorized service center. 