User Manual
59
INGENIA IG3T  Cod. 420120239 REV. 1.1
Wide indoor environment setting
MICROPHONE SETTING MENU
IG3T allows the input of a microphone with XLR connector. When using 
this source, it may be useful to apply a ltering to the signal to cut any 
unwanted frequencies (by a high-pass lter with adjustable cut frequency). 
Or it may be necessary to intervene (by a notch or band-stop lter with 
selectable band centre) to prevent any feedback (or Larsen effect). To 
perform one of these settings, or both of them, after accessing the 
MICROPHONE SETTING menu:
1.  Select and conrm HP lter (high-pass lter)
2.  Select and conrm the value of the high-pass lter cut frequency, with 
a range of 50 Hz – 200 Hz and a resolution of 10 Hz (select the “None” 
value if you wish to disable the lter) 
3.  Select and conrm “Antifeedback” (anti-feedback or anti-Larsen effect 
lter)
4.  Select and conrm the value of the band centre frequency, with a 
range of 260 Hz – 15000 Hz and a resolution of 10 Hz (select the 
“None” value if you wish to disable the lter)
5.  Return to the initial screen by selecting the “HOME” symbol
Microphone Setting Menu