Operating instructions
Troubleshooting
34
Control Panel Operation
(for additional information, please see the Special Operating Instructions for your specific hot tub)
TS702 Main Control Panel
Pump 1
Pump 1 is a 2 speed pump. Pressing once puts the pump into low speed, indicated on the LCD by a slow moving
pump icon . Pressing a second time activates Pump 1 to high speed (icon moves faster). To turn off,
press a third time (icon disappears from the LCD). If left running on high speed, Pump 1 will automatically turn
off after 30 minutes (2 hours on low speed). Refer to your Special Operating Instructions for a description of
which jets Pump 1 activates.
Pump 2
Pump 2 is a 1 speed pump. Pressing once puts the pump into high speed, indicated on the LCD by a fast
moving pump icon . To turn off, press again (icon disappears from the LCD). If left on, Pump 2 will automati-
cally turn off after 30 minutes. Refer to your Special Operating Instructions for a description of which
jets Pump 2 activates.
Blower
The blower activates all blower jets. Pressing once activates the blower, indicated on the LCD by a pump
icon . To turn off, press again (icon disappears from the LCD). If left on, the blower will automatically turn
off after 30 minutes.
Light
The underwater light and grab bar lights (if installed on your spa) are turned on or off by pressing the light
button. When turned on, the light icon is displayed on the LCD. In some cases, the light is turned low, medium,
high, off. The light button also controls any optional LED lighting if installed on your spa. By turning the LED
lights on and off, you can cycle through the various colors programmed into the LED controller (Blue/Green,
Purple, Blue, Green/Red, Green, Red, cycling through the colors, strobe effect).
Warm & Cool
The warm & cool buttons are used to change the temperature set-point of the spa. When either button is
pressed, “Set Temperature” is displayed on the LCD and the temperature can be adjusted. The minimum set
point is 80°, while the maximum is 104°.
Mode/Prog
Repeatedly pressing the mode/prog button will cycle through the available Spa Modes (Standard, Economy,
or Sleep - see descriptions below).
Time
Once the time is set, pressing the time button displays the time of day. To set the time, press ‘Time’
‘Mode/Prog’, then use ‘Warm’ & ‘Cool’ to select the hour. Once the hour is selected, press ‘Mode/Prog’ to
select the minutes and adjust using ‘Warm’ & ‘Cool’.
Indicator Lights: F1, F2, PL, & TL
F1 & F2 lights indicate programmed filtration cycles (see descriptions below).
PL indicates that the Control Panel is locked. Press ‘Time’ ‘Pump 1’ then ‘Warm’ to lock the panel. To unlock,
press ‘Time’ ‘Pump 1’ then ‘Cool’.
TL indicates that the temperature set-point is locked. Press ‘Warm’ ‘Time’ ‘Pump 1’ then ‘Warm’ to lock or
unlock the temperature set-point.
Troubleshooting
35
Heat Icons
When the temperature bars are alternating between top and bottom, the spa is measuring the water
temperature. When the bars progress from top to bottom, the spa water is being heating.
O
3
Ozone Icon
When displayed, the optional Ozonator (if equipped) is activated. If any Control Panel button is pressed, the
Ozone Icon will turn off and the Ozonator deactivated for 30 minutes after any button press. However, if the
optional ThermOzone system is installed it is always functioning regardless of the icon status.
Mode Icons
Either the Standard, Economy, Standard-in-Economy, or Sleep icon will be displayed depending on the mode
selected. See the descriptions below.
Spa Modes
Standar
d Mode constantly maintains the set temperature, assuming too many pumps aren’t running (see
Electrical Service, below). Heating will occur until the water reaches the next highest degree about the
temperature set-point. The Standard icon will be displayed unless the mode is changed.
E
conomy Mode allows the spa to heat only during the preset filtration cycles. In spas with continuous circulation
F1 & F2 Economy Cycle times must be set. Heating will occur until the water reaches the next highest degree
about the temperature set-point. The Economy icon will be displayed unless the mode is changed. Pressing the
‘Pump 1’ button will change the mode to Standard and display the Economy-in-Standard icon.
The spa will automatically revert to Economy mode after one hour (or instantly if you press ‘Mode/Prog’).
Sleep Mode
heats the spa to within 20° of the temperature set-point, but only during filtration cycles.
The Sleep icon will be displayed unless the mode is changed.
Additional Control Panels - supplied on some spa models
Wave Lounge Pump & Valve
If your spa is equipped with a Wave Lounge, these buttons control the
Wave Lounge Pump and Wave Lounge Valve. The Wave Lounge Pump is a 1
speed pump. Pressing once puts the pump into high speed. To turn off,
press again. If left on, the Pump will automatically turn off after 30 min-
utes. Once the Wave Lounge Pump is activated, press the Wave Lounge
Start/Stop button to begin the sequencing Wave Lounge action. Press
again to stop the valve and isolate specific jets. Refer to your Special
Operating Instructions for a description of which jets are controlled.
Control Panel Features
Power-Up Sequence
When power to the spa is turned on, the Main Control Panel will display a series of diagnostic numbers and/or
letters. When it displays “Pr”, it has finished initiation and enters into Prime Mode. Prime Mode will last for
4-5 minutes before automatically entering Run Mode. Run Mode can be entered earlier by pressing either
the ‘Warm’ or ‘Cool’ button.
Circulation Pump Operation
For spas equipped with a circulation pump, filtration and heating are controlled based on the mode selected
and electrical service in conjunction with the circulation pump.
Circulation Pump
The Circulation Pump will run 24 hours a day, 7 days a week to efficiently and effectively filter your spa water.
However, if the spa temperature exceeds the set-point by 3° the circulation pump will automatically turn off.
It will only turn back on during the preset filtration cycles or after the water temperature is within or below
3° of the set-point. Any time the circulation pump is running, your spa will be filtering water (unless your filters
are too dirty to permit water to pass through them).
Filtration Cycles
Filtration Cycles are set at the factory to occur from 8am-10am and 8pm-10pm. To change the filtration
cycle start and end times, press ‘Time’ ‘Mode’ ‘Mode’ ‘Mode’. Then use the ‘Warm’ and ‘Cool’ buttons to adjust
the start and end times for both filtration cycles. Press ‘Mode’ to select the chosen time and eventually
return to normal operation.
F1
F2
PL
TL
Auxiliary Pump
If equipped on your spa, Auxiliary Pump buttons control additional pumps