Instruction manual
4. Dedicated Options
4 - 2
4-1 Orientation option
Select the orientation option to be required for the spindle control based on the following table.
For each control function, availability of use differs depending on the specifications in the NC side, so
also refer to the manuals of NC side.
(a) No-variable speed control
(When spindle and motor are directly coupled or coupled with a 1:1 gear ratio)
Without orientation option With orientation option
Spindle
control item
Control specifications
Motor PLG
Motor PLG
with Z-phase
Motor PLG
with Z-phase
Magnetic
sensor
Spindle side
detector
(1020p/rev encoder)
Normal cutting control { { {
Constant surface speed
control (lathe)
{ { {
Speed
control
Thread cutting (lathe) × { {
1-point orientation
control
× × {
Multi-point orientation
control
× × {
Orientation
control
Orientation indexing × × {
Standard synchronous
tap
{ { {
S-analog
high-speed
synchronous
ta
p
control
Synchronous tap after
zero point return
× { {
This normally is not used
for no-variable speed control.
(Note 1) { : Control possible
× : Control not possible
(Note 2) The S-analog high-speed synchronous tap control is an option deferent from orientation. For details, refer to “2-2-2 (2)
Spindle drive unit function specifications list”. Setting position loop in the NC side is required.
(b) Variable speed control
(When using V-belt, or when spindle and motor are connected with a gear ratio other than 1:1)
Without orientation option With orientation option
Spindle
control item
Control specifications
Motor PLG
Motor PLG
with Z-phase
Motor PLG
with Z-phase
Magnetic
sensor
Spindle side
detector
(1020p/rev encoder)
Normal cutting control { { { { {
Constant surface speed
control (lathe)
U U U U {
Speed
control
Thread cutting (lathe)
× × × × {
1-point orientation
control
× × × { {
Multi-point orientation
control
× × × × {
Orientation
control
Orientation indexing
× × × × {
Standard synchronous
tap
S S S S {
S-analog
high-speed
synchronous
ta
p
control
Synchronous tap after
zero point return
× × × S {
(Note 1) { : Control possible
× : Control not possible
U : Control not possible when using V-belt
S : Control not possible when varying the speed with a method other than the gears and timing belt (when using V-belt
or timing belt).
(Note 2) The S-analog high-speed synchronous tap control is an option deferent from orientation. For details, refer to “2-2-2 (2)
Spindle drive unit function specifications list”. Setting position loop in the NC side is required.