Instruction manual

2. Specifications
2 - 13
(2) Spindle drive unit function specifications list
MDS-C1-SPA(H)-55300*
*: Option symbol
Function
None R D T RD RT
S analog command voltage input±10V
S analog command voltage input 0 to 10V
Machine ready complete input
Basic
function
Forward run/reverse run command input
Override analog input
Torque limit 1 to 3 input
Gear selection1, 2 input
Alarm reset input
Emergency stop input
Speed selection 1 to 3 input
Override valid/invalid input
L coil selection input
Index forward run/reverse run input - - -
Digital speed command input - - - -
S-analog high-speed tapping input - - - -
Sub-motor selection input
Speed meter output
Load meter output
Controller emergency output signal (contact output)
Pulse feedback output signal
Zero speed output signal
Up-to-speed output signal
Speed detection output signal
Torque reach output signal
In torque limit output signal
In motor forward run/reverse run output signal
In alarm output signal
In emergency stop output signal
In ready ON output signal
Current detect output signal
In coil changeover output signal
In L coil selected output signal
Alarm code output 1 to 4 signal
Orientation complete output signal - - -
Positioning complete output signal - - -
In 1-drive unit 2-motor changeover output signal
Miscellaneous function
In sub-motor selection output signal
Spindle motor + spindle motor
(FR-TK unit is required.)
1-drive unit
2-motor
changeover
Spindle motor + general-purpose motor
Magnetic sensor orientation (1 point) - - -
Encoder orientation (multipoint index) - - -
Orientation
Motor PLG orientation (multipoint
index ) - - -
12 bit binary - - - -
Signed binary - - - -
BCD3 digits - - - -
Digital speed
command
BCD2 digits - -
- -
1024p/rev encoder
specification
Only for encoder orientation - - - - -
1) Motor PLG orientation - - - - -
2) Magnetic sensor orientation - - - - -
Optional function
S-analog
high-
speed
tapping
Motor PLG
specification
3) Orientation not available - - - -
(Note 1)
: available -: not available
(Note 2)
For input excluding a basic function input, up to 12 points can be selected.
(Note 3)
For output, up to 8 points can be selected for open emitter, and up to 6 points for open collector.
(Note 4)
When using the override input terminal in S analog input, and when using the digital speed command, the override function
can not be used.
(Note 5)
When the orientation is not applied in the S-analog high-speed tapping specification, Z phase is not output from the pulse
feedback signal. A position loop of spindle must be operated in the NC side.