Audio Muting - The M4FM’s audio output can be set to automatically mute for received signals
with signal strength less than 45dBf.
Alarms
Program Loss Monitor Enabling any alarm will disable tuning, presets and band selection from the
WebServer and M4FM box User interface.
Program Loss Monitor (PLM) Connections The PLM provides four dry, floating relays with outputs
on a rear panel mounted DB15 connector to report selected alarm conditions, including loss of RF
carrier, audio loss, pilot preset, over modulation. Opto-isolated inputs will be triggered by a voltage of
5VDC. The GPIO Alarm output relays are Normally Open and will close when an alarm is active. See
figure 9 for the DB15 pin-outs:
Alarm Loss of: No Contact Common
Audio 5 10
RF Carrier 4 9
Pilot Present 3 8
Over Modulation 2 7
Empty 1 6
Empty 11 12
Reset 14 15
Pins not used 13
Figure 10.
Figure 11.
RF Carrier Loss - Alarm based on analog RF signal strength
Threshold: Navigate the arrow to Threshold and press ENTER to change the Threshold. A blinking
arrow will indicate the Threshold can be changed. Low, Medium and High are available to choose from.
Use the arrows to toggle through the choices. Press ENTER to make a selection and return to the RF
Carrier Loss menu. “LOW” option sets RF carrier loss threshold for approximately 10µV (25dBf);
“MED” option sets RF carrier loss threshold for approximately 100µV (45dBf); and “HIGH” option sets
RF carrier loss threshold for approximately 3KµV (75dBf).