Specifications
iv
HY-03 User Handbook
Safety Information
Safety of Mains Operated Equipment
This equipment has been designed to meet the safety regulations currently advised
in the country of purchase and it conforms to the safety regulations specied by
use of the CE Mark.
Warning : There are no user serviceable parts inside the equipment. If you should ever
need to look inside the unit, always disconnect the mains supply before removing the
equipment covers.
Warning: The HY-03 line socket should only be connected with apparatus
complying with BS6301, and the connection to the network must not be hard wired
Interconnection directly or indirectly with equipment ports marked in accordance with
BS6301 to unmarked ports may produce hazardous conditions on the network and
advice should be obtained from a competent engineer before such a connection is made.
Warning: This apparatus must be earthed by means of the earth connector on the rear
panel, and the connection to the telecommunications network should be removed
before disconnecting the earth. Disconnection of this earth connection may render the
equipment unsafe, with a consequential possible electrical shock hazard from exposed
metallic parts.
Warning: The barriered ports ‘LINE’ and ‘HANDSET’ must not be connected directly or
indirectly to the un-barriered ports, ‘MIC/LINE INPUT’, ‘OUTPUT’ or ‘REMOTES’.
Voltage Setting Checks
The mains input voltage selector switch on the rear panel of the equipment sets the
operating voltage of the HY-03 to be either 115V or 230V. Ensure that the machine
operating voltage is correct for your mains power supply. The safety specication of your
HY-03 complies with local requirements and must be earthed through the mains connector.
Fuse Rating
The HY-03 is supplied with a single fuse in the live conducting path of the mains power
input. For reasons of safety it is important that the correct rating and type of fuse is
used. Incorrectly rated fuses could present a possible re hazard, under equipment fault
conditions. The fuse ratings for the HY-03 are:
115V operation: 200mA 5 x 20mm SB
230V operation: 100mA 5 x 20mm SB
The active fuse is tted on the outside rear panel of the unit. If you change the voltage of
the HY-03, make sure to change the fuse also.
SAFETY INFORMATION