Specifications
HY-03 User Handbook
15
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION
3
Please note the Lamp output is only capable of driving loads up to 40mA , when
connecting any loads the current should be limited to this value using a series resistor.
For example a 390 ohm resistor would limit the current to 38mA.
To connect/disconnect the unit pins 1 and 2 should be connected together via a
contact closure or equivalent. Care should be taken that pin 3 is not connected to pins
1 or 2 and that incompatible external signals are not used. Incorrect conguration can
result in the failure of the connect/disconnect transistor and protection diode which
leaves the unit permanently latched in a connected state and therefore unusable.
As this fault is caused by using the unit outside of its recommended operating
conditions it will not be covered under warranty.
Telephone Handset
This is the connection for a telephone handset and is an RJ11 socket. There is a converter
supplied with the HY-03 for accepting a standard BT605A telephone plug.
Telephone Line
This is the telephone line connection and is an RJ11 6/4 socket. Two cables are supplied with
the unit, to connect this either to a UK BT line jack socket, or an RJ11 socket. The telephone
line is connected via Pins 3 and 4 on the RJ11 and Pins 2 and 5 on the BT Plug (the latch
adjacent to Pin 6).
RJ11 Telephone Connections
Pin 1 : N/C
Pin 2 : Earth recall
Pin 3 : Telephone line A
Pin 4 : Telephone line B
Pin 5 : Ringer
Pin 6 : N/C
Note: When not used in the UK, connect pins 3 and 4
only for operation.
Mains Input
The power supply is connected via an IEC Connector (CEE22, 230V - 50Hz, or 115V – 60Hz).
Protective Earth Terminal
This earth bond screw terminal is a screen terminal which must be connected to an
earth point.
Pin 6 Pin 1
BT Telephone Connections
Pin 1 : N/C
Pin 2 : Telephone line A
Pin 3 : Ringing
Pin 4 : Connected for neatness only
Pin 5 : Telephone line B
Pin 6 : N/C
RJ11 Socket
BT Plug
6
5
4
3
2
1