Specifications
HY-03 User Handbook
13
CONFIGURATION & CONTROLS
CONFIGURATION & CONTROLS
2
County Frequencies Type Details Jumper(s)
set on JP…
Netherlands 450Hz Continuous 5
Norway 425Hz Continuous 1 + 5
Poland 425Hz Continuous 2 + 5
Portugal 425Hz Continuous 1 + 2 + 5
South Korea 350Hz and 440Hz Continuous 1 + 2 + 4 + 5
Spain 425Hz Continuous 3 + 5
Sweden 425Hz Continuous 1 + 3 + 5
Switzerland 425Hz Continuous 2 + 3 + 5
Taiwan 350Hz and 440Hz Continuous 3 + 4 + 5
United
Kingdom
350Hz and 440Hz Continuous
& Cadence
750ms on,
750ms pause
1 + 2 + 3 + 5
United States 440Hz and 480Hz Continuous 4 + 5
Table D : Dial tone disconnect options
The unit can be programmed with other settings, so please contact us if you need the
settings for a dierent country to be implemented. In this case, it would be useful to have an
audio recording of the dial-tone and a specication of the dial tone parameters.