Automatic Telephone Hybrid User Handbook
HY- 03 USER H A N D BOOK HY-03 USER HANDBOOK This handbook is for use with the following products : HY-03 Automatic analogue TBU with ringing detector, free standing HY-03 (US) Automatic analogue TBU with ringing detector, free standing US Version HY-03S Automatic analogue TBU with ringing detector, 19” rack mounted HY-03S (US) Automatic analogue TBU with ringing detector, 19” rack mounted US Version HY-03T Twin automatic analogue TBU with ringing detector, 19” rack mounted HY-03T (US) Twin automatic anal
CONTENTS Contents Warranty And Safety Information i i iii iii iv iv iv v v vi vi vi vi vii viii Introduction 1 What is a Telephone Hybrid ? Integrated Ringing Detector Available Formats Installing the HY-03 TBU Using the HY-03 Receiving a Call Making a Call FAQ (Frequently Asked Questions) 2 2 2 3 5 5 5 5 Configuration & Controls 7 Front Panel Controls Power LED Indicator Line Connect Switch Rear Panel Controls Adjusting the Output Level Adjusting the Microphone Gain Level Mic/Line Input Select Swi
CON T E N TS CONTENTS Telephone Line Mains Input Protective Earth Terminal Technical Specification Physical Specification Accessories Approvals Information Manufacturer Equipment Type BABT Approval Numbers Functions Specified Systems Ringer Equivalence Number Accessory Ports Conditions Series Connection Facilities Statutory Mark Figures Table A : Packing List iii Table B : Power Connections v Table C : Mains Lead Table Figure 1-1 : HY-03 & HY-03 US Front & Rear vi 2 Figure 1-2 : HY-03S & HY-03S US
WARRANTY Warranty Warranty and Liability Important: the purchaser is advised to read this clause (a) The Company agrees to repair or (at its discretion) replace Goods which are found to be defective (fair wear and tear excepted) and which are returned to the Company within 12 months of the date of despatch provided that each of the following are satisfied: notification of any defect is given to the Company immediately upon its becoming apparent to the Purchaser; (ii) the Goods have only been operated un
WA RR A N T Y WARRANTY for death or personal injury to the extent that it results from the negligence of the Company, its employees (whilst in the course of their employment) or its agents (in the course of the agency); (ii) for any breach by the Company of any statutory undertaking as to title, quiet possession and freedom from encumbrance.
WARRANTY Unpacking the HY-03 The HY-03 is shipped with the following equipment. Please check your packaging to ensure that you have all of the items below. If anything is missing, please contact the supplier of your equipment immediately. Quantity HY-03 & HY-03S 1 1 1 Quantity HY-03T 2 2 2 1 2 1 1 2 1 Table A : Packing List. Each HY-03 is shipped in protective packaging and should be inspected for damage before use.
SAFETY INFORMATION Safety Information Safety of Mains Operated Equipment This equipment has been designed to meet the safety regulations currently advised in the country of purchase and it conforms to the safety regulations specified by use of the CE Mark. SAFE T Y IN FORMAT I ON Warning : There are no user serviceable parts inside the equipment. If you should ever need to look inside the unit, always disconnect the mains supply before removing the equipment covers.
SAFETY INFORMATION Power Cable and Connection An IEC power connector is supplied with the HY-03 which has a moulded plug attached – this is a legal requirement. If no moulded plug has been supplied with your HY-03, please contact your supplier, because an IEC connector is always supplied from the Sonifex factory. If for any reason, you need to use the HY-03 with a different power cable, you should use the following wiring guidelines Connection Earth (E) Neutral (N) Live (L) Table B : Power Connections.
SAFETY INFORMATION Ordering the Correct Mains Lead When ordering a TBU from Sonifex, it is helpful if you can specify your required operating voltage and mains lead. After the product code add: UK, for 230V, UK 3 pin to IEC lead EC, for 230V, European Schuko 2 pin to IEC lead SAFE T Y INFORMAT I ON US, for 115V, 3 pin to IEC lead vi AU for 230V, Australasian 3 pin to IEC lead Table C : Mains Lead Table. E.g. order HY-03S UK for a UK IEC lead to be supplied.
SAFETY INFORMATION WEEE & RoHS Directives - Sonifex Statement The Waste Electrical and Electronic Equipment (WEEE) Directive was agreed on 13 February 2003, along with the related Directive 2002/95/EC on Restrictions of the use of certain Hazardous Substances in electrical and electronic equipment (RoHS).
REPORTING FAULTS Reporting Faults REP ORT I N G FAU LTS Although this Sonifex product is manufactured to the highest standards, it is possible that minor faults may appear in the equipment over its normal lifetime. If you find any problems with the HY-03, please contact your Sonifex distributor, or contact Sonifex directly at the following address, or fax with a copy of this completed sheet : To : Sonifex Ltd, From: Name 61, Station Road, Position Irthlingborough, Company Northants.
INTRODUCTION 1 1 Introduction The HY-03 is a high quality analogue telephone hybrid, which is suitable for most general telephony applications and is often used in radio and TV stations, bingo halls and dealing floors. The analogue HY-03 telephone hybrid is the replacement for the HY-02, which for many years has set the standard as an excellent value, high quality telephone hybrid. • Fully automatic – adapts to varying line conditions and has automatic signal limiting.
1 INTRODUCTION What is a Telephone Hybrid? Telephone hybrids (or telephone balance units, TBUs) provide the interface between professional audio equipment and the public telephone network. They provide protection for your equipment and the public telephone lines, allowing for varying line signals and line conditions.
INTRODUCTION 1 HY-03S & HY-03S US Automatic analogue TBU with ringing detector, 1U 19” rack mounted Figure 1-2 : HY-03S & HY-03S US Front & Rear I N T ROD U C T ION HY-03T & HY-03T US Twin automatic analogue TBU with ringing detector, 1U 19” rack mounted Figure 1-3 : HY-03T & HY-03T US Front & Rear Installing the HY-03 TBU Connect the earth and mains power connections as per the information given in the Warranty and Safety Information section of the handbook, and ensure that the mains input voltage s
1 INTRODUCTION The telephone line socket is connected to the telephone network using the cable provided (either RJ11 to RJ11, or RJ11 to BT plug). A simple telephone handset can be used to take and make calls when plugged into the equipment handset connector. An adapter is provided if the handset is fitted with a BT plug as standard. INTROD U C T I ON A remote switch may be connected at the Remotes socket in order to control the line connect switch from say, the telco channel of a mixing desk.
INTRODUCTION 1 Using the HY-03 Receiving a Call With the equipment connected as in Figure 1-4 calls may be received and detected by the ringer in the telephone handset. To receive the call, lift the handset and establish contact with the caller. The call may be diverted to the telephone hybrid by pressing either the front panel mounted line connect switch or by means of the remote divert switch (if connected). Note : The remote lamp tally mimics the front panel line connect switch lamp, i.e.
1 INTRODUCTION Q: What type of remote lamp will the HY-03 drive? A: The remote lamp type should be 15V at 40mA max. When connecting any loads the current should be limited to this value using a series resistor. For example a 390 ohm resistor would limit the current to 38mA. INTROD U C T I ON To connect/disconnect the unit pins 1 and 2 should be connected together via a contact closure or equivalent.
CO NFI G U R AT ION & CONTROLS 2 Configuration & Controls Front Panel Controls Power LED Indicator Line Connect Switch Power LED Indicator The power LED indicates that the equipment is powered and operational when illuminated. Line Connect Switch This is the front panel button used to connect calls to, and disconnect calls from, the telephone line. The switch will illuminate to indicate the call has been connected.
2 CO N F I G U R AT I ON & CO NT ROLS Adjusting the Microphone Gain Level The Mic Level Preset Pot controls the level of the input signal when the input signal mode is set to Mic. The input signal level in Line mode is factory set and is not affected by this control. The Mic Input will accept 200 ohm microphone level signals and is balanced/ floating with a maximum gain of 74dB. Use a jeweller’s screwdriver to adjust the gain between 74dB and 40dB.
CONFIGURATION & CONTROLS 2 design exchange systems are designed to have a K-break signal lasting 50ms). British Telecommunications plc may, in some situations where no end of call signal is available, be able to provide one at the request of a UK customer. Line Polarity Reversal Disconnect Enable - SW2 and JP5 When SW2 is enabled (ON) (and for serial number HY-03 units after HY000323 when JP5 is on), the HY-03 will automatically disconnect from the telephone line by detecting the line polarity reversal.
2 CONFIGURATION & CONTROLS HY-03 Internal Controls & Adjustments See page v for information on opening the HY-03 RV7 Res Set RV6 Limit Level CON FIGUR ATION & CON T ROLS JP1 RV2 RV4 Noise Gate Disable JP2 JP3 Cap Set Res Auto Cap Auto Disable Disable Noise Gate Threshold RV8 RV5 Sample Threshold Plug-in Header JP16 JP1 Rings Optional HY-03DTD Board Mounting screw on a pillar JP5 Output Level RV3 Mic Gain Line Reverse JP4 K-Break On units serial number HY000323 upwards RV1 Figure 2-4
CONFIGURATION & CONTROLS 2 Note : The noise gate threshold is factory set for optimum performance, so will not normally need adjustment. Important Note : There are a number of other controls which are factory set, or should only be used when testing/aligning the product. These are RV2, RV5, RV6, RV7 and RV7 jumpers JP2 and JP3. Please note that these controls should not be adjusted in normal Res Set operation and could damage the performance of your product if altered.
CON FIGUR ATION & CON T ROLS 2 12 CONFIGURATION & CONTROLS County Frequencies Type Details Jumper(s) set on JP… Austria 440Hz Continuous - 1 Avaya PBX 400Hz Cadence 375ms on, 375ms pause 2+3+4+5 Belgium 450Hz Continuous - 2 Bulgaria 425Hz Cadence 250ms on, 750ms pause, 750ms on, 1000ms pause 1+2 Cyprus 350Hz and 450Hz Continuous - 3 Czech Republic 425Hz Continuous - 1+3 Denmark 425Hz Continuous - 2+3 Finland 425Hz Continuous - 1+2+3 France 440Hz Continuous
CONFIGURATION & CONTROLS Frequencies Type Details Netherlands 450Hz Continuous 5 Norway 425Hz Continuous 1+5 Poland 425Hz Continuous 2+5 Portugal 425Hz Continuous 1+2+5 South Korea 350Hz and 440Hz Continuous 1+2+4+5 Spain 425Hz Continuous 3+5 Sweden 425Hz Continuous 1+3+5 Switzerland 425Hz Continuous 2+3+5 Taiwan 350Hz and 440Hz Continuous 3+4+5 United Kingdom 350Hz and 440Hz Continuous & Cadence United States 440Hz and 480Hz Continuous 750ms on, 750ms pause Ju
3 TE C H N I C A L S PE C I FI C AT I ON Technical Specification HY-03 Connection Details All of the connections are located on the rear of the HY-03 : TECHNIC AL SP E CI FI C AT I ON Line Mic/Line Output Input Remotes Telephone Handset Protective Earth Terminal Mains Input Telephone Line Figure 3-1 : HY-03 Rear Panel Connections Line Output The line output is an XLR 3 pin male connector (XLR-3-32, 50 ohm balanced floating).
T E C HNI C AL SP ECIFIC ATION 3 Please note the Lamp output is only capable of driving loads up to 40mA , when connecting any loads the current should be limited to this value using a series resistor. For example a 390 ohm resistor would limit the current to 38mA. To connect/disconnect the unit pins 1 and 2 should be connected together via a contact closure or equivalent. Care should be taken that pin 3 is not connected to pins 1 or 2 and that incompatible external signals are not used.
3 TE C H N I C A L S PE C I FI C AT I ON TECHNIC AL SP E CI FI C AT I ON Technical Specification Feature Value Input impedance – line mode (clean feed) 10kΩ balanced 0dB, optimum working input level 0 to+8dBu Input impedance – microphone mode 200Ω balanced Clean feed limiting input +4dBu Microphone level range From 74dB to 40dB adjusted by preset pot Bandwidth to telephone line 250Hz – 4kHz, -3dB ref 1kHz Telephone line impedance Nominally 600Ω Telephone line impedance range 300Ω to 1500Ω
T E C HNI C AL SP ECIFIC ATION 3 Accessories Description HY-03DTD Dial tone detect add-on board HY-03CON Front panel conversion kit, HY-03S 19” rack-mount front to HY-03 free standing HY-03SCON Front panel conversion kit, HY-03 free standing to HY-03S 19” rack-mount front HY-03TCON Front panel conversion kit, HY-03 or HY-03S, to HY-03T 19” rack-mount front Approvals Information Sonifex is a BABT approved manufacturing facility with a license to build telecommunications equipment and all telecom p
3 TE C H N I C A L S PE C I FI C AT I ON Branch System for PSTN is given in BS6789 : Section 6.1 : 1986 Clause 2.9; including the note to that clause. Ringer Equivalence Number The REN=1 marking on the rear of this equipment relates to the performance of the apparatus when used in combination with other items of apparatus. TECHNIC AL SP E CI FI C AT I ON The REN indicates the maximum number of items that should be connected simultaneously to the line.
12 HY-03 User Handbook 19
w w w. s o n i fe x . c o. u k t:+44 (0)1933 650 700 f:+44 (0)1933 650 726 s a l e s @ s o n i fex . co.