Specifications
83
Issued: 28.02.2005
Strider MD 4 Plus
Please give used or damaged batteries back to your dealer.
He will ensure that they are properly disposed of.
➨
Handling damaged batteries:
When handling damaged batteries or objects which
have been soiled with acid, you must always wear:
- protective goggles
- acid-proof gloves
- respiratory protection
Always wash soiled objects and tools with plenty of water.
➨
➨
Transporting damaged batteries:
Always wear protective goggles and acid-proof gloves.
Always transport and store batteries in an acid-proof container.
➨
➨
Caution acid!
• Observe safety information in chapter 1.6!
BATTERIES ARE HAZARDOUS WASTE!!
Used and defective batteries must be properly disposed
of and only handed over to the correct disposal points.
Repairs - batteries
Risk of accidents!
• Refitting the battery may only be carried out by your dealer.
• 10 A fuse (1)
Only replace the batteries with the following battery types:
12 V / 38 Ah - 20h (32 Ah - 5H), liquid acid deep cycle batteries
Max. battery size (l x w x h) = 197 x 165 x 170 mm
You may
not
*use wet cell batteries with detachable cover caps.
17.6.1 Disposal of used or damaged batteries
17.6 Batteries
17.5.3 Battery charger fuse