Specifications

30
M
• the Time appears with the Hour setting (Fig. 28a) flashing
• press Select (Right) button until the correct Hour appears.
• press Advance (Left) button 1 time to accept the setting displayed
• the Minute setting (Fig. 28b) flashes
• press Select (Right) button until the correct Minute appears.
• press Advance (Left) button to accept the setting displayed, and either -
• revert to Surface Mode (if this setting was changed), or -
• advance to Set: Sampling Rate (Date/Time settings not changed)
SAMPLING RATE
Sampling Rate is the Time, or Depth, interval at which data samples will be
recorded during a dive for subsequent download to the Dive Downloader PC
software program. The set point has 'no effect' upon displayed data or data
stored in the unit's viewable Log.
Rates available are 2 FT (.5M), 5 FT (1.5 M), 10 FT (3 M), 2 SEC, 5 SEC, 10
SEC, 15 SEC, 20 SEC, 25 SEC, 30 SEC.
When lower rates (e.g., 2 FT, 2 SEC, etc.) are selected more samples are re-
corded per dive making the PC profile graphs smoother. However, since more
memory is used per dive, fewer dives can be stored for download. Also, lower
sampling rates require longer periods of time to download (up to 45 minutes).
Fig. 28 - Set Time of Day
a
b