Specifications
16
One Double Beep = Potential Danger
During situations that may pose potential danger, one Double Beep is emitted
from the 500AI. These situations include:
• Entry into decompression.
• Breathing Gas Time Remaining decreasing to 5 minutes.
• Partial pressure of oxygen (PO2) equal to or greater than 1.40 ATA.
Continuous One Beep per Second = Immediate Danger
When the 500AI senses immediate danger to you, it emits One Beep per Sec-
ond until the situation is corrected, if the Audible Alarm feature is set ON (de-
scribed later). If the Audible Alarm feature is set OFF, you will be alerted in-
stead by one Double Beep. Immediate Danger situations include:
• Ascending to a depth shallower than a Required Stop Depth.
• Upon surfacing, if shallower than a Required Stop Depth for less than 5
minutes.
• Partial pressure of oxygen (PO2) equal to or greater than 1.60 ATA.
• Ascending at a rate that exceeds 60 fpm (18 mpm).
• Descending deeper than the Depth Alarm Set Point.
• Gas Time Remaining equals zero (0:00).
• Oxygen accumulation greater than the allowed per dive or 24 hour limit.
BEEP!
BEEP!
BEEP...
BEEP...