Instruction manual
Installation Page 27
Connecting Alarm Output Module Wires
If using solar power in conjunction with the Alarm Output Module (AOM),
connect the system according to the wiring diagram below.
✦ Plug the free end of the power cable into the Power jack on the RM.
✦ On the other side of the terminal block, connect the black wire from the RM
power cable to terminal 1 (grey) and the red wire to terminal 2 (orange).
Red
Wht
Wht
Black
Black
Terminal
Block
12
Regulator
B3
B4
P1
B2
B1
Yel
Grn
Wht
Blk
Wht
Blk
Supplied with
Solar Power Kit
Battery
Blk
Blk
Red
Tab Adapter
_
+
RM
Power
Cable
Yel
Grn
Alarm Output
Module
+
_
B
Contacts