Product specifications
5-5
WeatherLink
Function Specification
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . -40° to +140°F (-40° to +60°C)
Output Contact Closures . . . . . . . . . . . . . . . . . . . . . . . . . 4 Alarm Contact Specifications, Terminal Block with stainless steel
cage clamp screw terminals.
Each of the four output contacts is rated as follows:
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Photo-coupled MOS FET
Load Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28VAC or 48VDC
Peak Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 60 V, maximum
Load Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 1.8 A, continuous maximum at 77°F (25°C), derated to 0.7 A at 185°F,
(85°C)
Peak Load Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 A for 100 msec., maximum
ON Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.12 Ohms, maximum
OFF Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 uA, maximum
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 550 mW, maximum
Output Contact Closure Functions (Set through the configuration software utility):
Station Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allows user to configure available test parameter list based on station
model and accessories.
Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allows user to enter test parameters in English or metric.
Available Test Parameters. . . . . . . . . . . . . . . . . . . . . . . . Outside Temperature, Outside Humidity, Outside Dewpoint, Current
Wind Speed, 10 min Avg. Wind speed, Wind Direction, Wind Chill,
Outside Heat Index, Barometer Value, Barometer Trend: (Rising
Rapidly, Rising Slowly, Steady, Falling Slowly, Falling Rapidly), Daily
Rain, Storm Total Rain, Monthly Rain, Yearly Rain, Rain Rate, Solar
Radiation, UV Radiation, Inside Temperature, Inside Humidity, Inside
Dewpoint, Inside Heat Index, Extra Temperature (1- 8: # based on Tx
ID), Extra Humidity (1- 8: # based on Tx ID) Daily ET, Monthly ET,
Yearly ET, Leaf Wetness (1-2), Soil Moisture (1-4), Leaf Temperature
(1-2), Soil Temperature (1-4), Time, Transmitter Battery Status (ID# 1-
8), Repeater Battery Status (ID# A-H), Console Batteries, ISS
Reception (% since midnight)
Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Greater Than or =, Less Than or =, Between, Not Between, True (or
False, used for Barometer Trend and Battery Status Parameters),
Trending, Equal, Minus (Difference), Missing (if data is dashed)
Logical Grouping Options . . . . . . . . . . . . . . . . . . . . . . . . Alarm Triggers on any user-selected logical grouping of up to 8 test
conditions (up to 7 if using the Minus or Difference Test Condition/
Check Type): OR (any test conditions can be true), AND (all test
conditions must be true), XOR (only one test condition can be true),
DONE (only on test condition used)
Alarm Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The log will consist of which output became active, which parameters
caused the alarm to become active (useful for the AND type alarm)
along with the date and time that the alarm became active. This log is
cleared whenever any of the output alarms are cleared. Can be
activated or deactivated by the user.
Output Contact Closure Functions
Duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 255 minutes (user selectable). Determines how long the alarm
output should stay active once it is triggered. Default = 10 minutes
Reactivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 255 minutes (user selectable). Determines how long to leave the
alarm output deactivated once it is deactivated. Default = 0.
Pulse Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 9999 milliseconds (user selectable). Default = 2000 milliseconds
(2 seconds).
Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous or Pulse (1-time) (user selectable). Determines whether a
pulse for alarm activation is continuous throughout the activation time
or a one time pulse. Pulsed relay oriented devices will require the one-
time pulse. Default = Continuous
Circuit Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normally Open or Normally Closed (user-selectable). Determines
whether the circuit stays open or closed when no alarms are active. The
opposite behavior occurs for an active alarm condition. Normally closed
is the most typical operation for Irrigation controller use. Default =
Normally Closed.
Test Mode Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Available. Continuous, Open, or Closed circuit (user-selectable).