Product specifications
(
510
)
732-9229
•
FAX
(
510
)
670-0589
•
sales@davisnet.com
•
www.davisnet.com
3465 Diablo Ave., Hayward, CA 94545-2778
2-10
Vantage Pro2
TM
Accessories
Temperature (Air)
Resolution and Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .1°F or 1°C. Celsius is converted from Fahrenheit and rounded to the
nearest 1°C
Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40° to +150° F (-40° to +65° C)
Sensor Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1°F (±0.5°C) typical (see chart)
Radiation Induced Error . . . . . . . . . . . . . . . . . . . . . . . . . .+2°F (1°C) at solar noon (insolation = 1040 W/m2, avg. wind speed
2 mph (1 m/s)) (reference: RM Young Model 43408 Fan-Aspirated
Radiation Shield)
Update Interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 seconds (depending on ID code)
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High and Low Thresholds from Instant Reading
Temperature Chart
Package Dimensions
Product #
Package Dimensions
(Length x Width x Height)
Package Weight UPC Codes
6382
8.75" x 7.75" x 5.25"
(223 mm x 197 mm x 134 mm)
3.5 lbs. (1.6 kg)
011698 00743 1
6382OV 011698 00744 8
Temperature Accuracy
0.0
1.0
2.0
3.0
4.0
5.0
-40 -20 0 20 40 60 80 100 120 140
Temperature (°F)
Temperature Accuracy
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
-40-30-20-10 0 102030405060
Temperature (°C)
Accuracy (°F) Accuracy (°C)