Linking
Before a belt station and a gateway can be connected, they must first be Linked. As a security
measure, the close-link feature requires devices to be in proximity of about 1 to 3 ft (0.3 to 0.9m)
in order to successfully link. This ensures that the units are not inadvertently linked with other
units on the premises.
Linking procedure:
1. Ensure units are within 1 to 3 ft (0.3 to 0.9m) of each other.
2. Ensure the U9110-BSW is not already connected (see Status Indication).
3. Simultaneously (within 1-2 sec) press and release the PTT button on the U9110-BSW and
the gateway to link with.
4. Amber LED’s will flash on both devices. A momentary red LED indicates a successful
close-link.
5. Upon successful link the U9110-BSW will attempt to establish a connection with the
gateway.
6. Upon successfully establishing connection the LED will flash green, a voice alert will be
heard (see Table 1), and user side-tone will be enabled (see Communication).
7. Link and connection are now complete.
Each belt station is able to be linked to only one gateway at a time. A gateway can have up to
five belt stations linked and be connected to four of those five at one time.
Tip:
Once linked, the devices will not need to be linked again unless they are purged (see
Purging).
Status Indications
The power button has a multi-color LED in the center which serves as a status indication for the
belt station. Table 1 below lists these states.
Table 1: LED Status Indication
LED Color Blink Rate Status
Red Solid Initializing/power up
Red Solid Close-link successful
Red Any Low battery (approx. 1 hr remaining)
Orange Slow Idle/Disconnected
Orange Fast Link/Connection in progress
Orange Solid PTT asserted
Green Slow Connected
In addition to the LED, the belt station provides audio feedback for certain conditions as well.
Table 2 below lists these conditions.