User's Manual
4of8
19541P‐42(02‐11)
L
L
i
i
n
n
k
k
i
i
n
n
g
g
Beforeabeltstationandagatewaycanbeconnected,theymustfirstbelinked.Asasecurity
measure,theclose‐linkfeaturerequiresdevicestobeinproximityofbetween1to3ft(0.3to
0.9m)inordertosuccessfullylink.Thisensuresthattheunitsarenot
inadvertentlylinkedwith
otherunitsonthepremises.
Linkingprocedure:
1. Ensureunitsarewithin1to3ft(0.3to0.9m)ofeachother.
2. Simultaneously(within1‐2sec)pressandreleasetheLINKbuttonontheU9921‐GUVand
thepowerbuttononthebeltstationtolink
with.
3. AmberLED’swillflashonbothdevices.AmomentaryredLEDindicatesasuccessful
close‐link.
4. UponsuccessfullinktheU9921‐GUVwillattempttoestablishacon nect ionwiththebelt
station.
5. UponsuccessfullyestablishingconnectiontheLEDonthecontrollerwillflashagreen
pattern
correspondingtothenumberofbeltstationsconnected.
Tip:
Oncelinked,thedeviceswillnot needtobelinkedagainunlesstheyarepurged(see
Purging).
Eachbeltstationisabletobelinkedtoonlyonegatewayatatime.Agatewaycanhaveuptosix
beltstationslinkedandbeconnectedtofourofthose
sixatonetime.
S
S
t
t
a
a
t
t
u
u
s
s
I
I
n
n
d
d
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Thefrontpanelhasamulti‐colorLEDinthecenterwhichservesasastatusindicationforthe
gateway.Table1belowliststhesestates.
Table2:LEDStatusIndications
LEDColor BlinkRate Status
Red Solid Initializing/powerup
Red Once ConnectionDropped
Red Once ConnectionEstablished
Red Any Lowbattery(approx.1hrremaining)
Orange Slow Idle/Disconnected
Orange Fast Link/ConnectioninProgress
Orange Solid PTTasserted
Green Slow Connected(patternindi cates
numberofbeltstationsconnected)