Installation manual
1
9532P-62 (03-11)   
5
of 32
1.  Mounting the Master Station 
P
arts/Tools Required 
q   U
9800S Series 9800 Intercom System Master Station (40898G-01) 
q   Master Station Mounting Kit (40688G-63) 
o  4 neoprene washers 
o  4 Stainless steel screws 
o  4 Nylon washers 
o  4 Stainless steel washers 
o  4 Stainless steel nuts 
q   Pencil/Pen 
q   Drill 
q   7/32-inch Drill Bit 
q   Drilling Template (Figure 3) 
q   Philips-head screwdriver 
q   11/32-inch nut driver or wrench 
Procedure 
L
ocation Considerations 
  Select a location on a flat surface that is out-of-the-way, and provides adequate room to attach all 
cables. Be sure to allow for internal access, as adjustments may be necessary. The Master 
Station is weather resistant, however the mounting location should be chosen to minimize direct 
exposure to the elements. 
Mounting 
q   Using the mounting template in Figure 3, mark and drill the (4) 7/32-inch holes through the 
mounting surface. 
q   Remove the cover and position the Master Station on the mounting surface and confirm 
mounting holes. 
q   Mount the Master Station using the hardware provided. Slide nylon washer over each screw 
before using. Place a neoprene washer between the Master Station and the surface where 
each screw is located. Use a stainless-steel washer on the back side of the surface under 
each nut. Secure tightly with a stainless-steel lock-nut. See Figure 2. 
q   The installer may wish to leave the cover removed from the Master Station, as internal 
adjustments may be necessary later during the installation. Be sure to replace cover and 
tighten the four screws when adjustments are completed. 