Specifications
85 of 104
MINI SLAVE UNIT Bidder Complies: Yes ( ) No ( )
An electric water level gauge shall be provided in the cab that registers water level by means of five (5)
LEDs. They shall be at 1/4 level increments with a tank empty LED. The LEDs shall be a bright type
that is readable in sunlight, and have a full 180-degree of clear viewing.
The water level gauge in the cab shall be activated when the pump is in gear.
FOAM LEVEL GAUGE Bidder Complies: Yes ( ) No ( )
A foam level gauge shall be provided on the operator's panel, that registers foam level by means of
nine (9) LEDs. There shall also be a mini foam level gauge with five (5) LEDs in the cab. They shall be
at 1/8 level increments with a tank empty LED. The LEDs shall be a bright type that is readable in
sunlight, and have a full 180 degree of clear viewing. The gauge shall match the water level gauge in
the pressure controller.
To further alert the pump operator, shall have a warning flash when the tank volume is less than 25
percent, and shall have Down Chasing LEDs when the tank is almost empty.
The level measurement shall be ascertained by sensing the head pressure of the fluid in the tank or
cell. This method provides accuracy with an array of multi-viscosity foams.
The foam level gauge in the cab shall be activated by pump is in gear.
SIDE CONTROL PUMP OPERATOR'S/PUMP PANEL LED LIGHTING Bidder Complies: Yes ( )
No ( )
Illumination shall be provided for controls, switches, essential instructions, gauges, and instruments
necessary for the operation of the apparatus and the equipment provided on it.
The pump panels shall be illuminated by four (4) Truck-Lite, Model 44308C white 12 volt DC LED lights
installed on the back of the cab, two (2) each side. These lights shall be activated with the perimeter
lights.
The pump operator's panel shall be illuminated by three (3) Fire Research Model 115-Q01 white 12 volt
DC LED lights on the forward wall near the doorframe. These lights shall be activated when the
battery switch is on and the pump operator’s compartment door is opened.
There shall be a small white LED pump engaged indicator light installed overhead. This light shall be
activated when the battery switch is on and the pump is engaged.
AIR HORN SYSTEM Bidder Complies: Yes ( ) No ( )
Two (2) Hadley round air horns with 6.00" bell shall be provided and located, in the front bumper,
recessed one each side inside the frame rails. The horn system shall be piped to the air brake system
wet tank utilizing 0.38" tubing. A pressure protection valve shall be installed in-line to prevent the loss
of air, in the air brake system.
AIR HORN CONTROL Bidder Complies: Yes ( ) No ( )
The air horns shall be actuated by a chrome push button located on the officer side of the engine
tunnel and by the horn button in the steering wheel. The driver shall have the option to control the air
horns or the chassis horns from the horn button by means of a selector switch located on the
instrument panel.
ELECTRONIC SIREN Bidder Complies: Yes ( ) No ( )
A Whelen, Model: 295SLSC1, electronic siren with detachable noise canceling microphone shall be
provided.
The siren shall be active when the battery switch is on and that emergency master switch is on.
Electronic siren head shall be recessed in the passenger side inside switch panel.