The elbow will be the VLH, which incorporates an exclusive thread design to automatically relieve
stored pressure in the line when disconnected. (no exception)
ELBOW, 4.00" OUTLET Bidder Complies: Yes ( ) No ( )
The 4.00" outlet shall be furnished with a 4.00"(F) National Standard hose thread x 5.00" Storz elbow
adapter with Storz cap.
DISCHARGE OUTLET CONTROLS Bidder Complies: Yes ( ) No ( )
The discharge outlets shall incorporate a quarter-turn ball valve with the control located at the pump
operator's panel. The valve operating mechanism shall indicate the position of the valve or an indicator
shall be provided to show when the valve is closed.
The passenger side discharges shall be controlled by an Akron 9315 Navigator controller with the
manual override located on the passenger side pump panel. In addition to valve position, each Akron
9315 Navigator controller shall include a pressure display.
The controller unit shall have solid state electronics to provide easy, two (2) button open and close
valve position capability with valve position indicator lights, and current limiting valve motor stopping
capability. The unit shall be in water resistant brass housing and shall come with all required
installation cables and harnesses.
All other outlets shall have manual swing handles that operate in a vertical up and down
motion. These handles shall be able to lock in place to prevent valve creep under pressure.
CROSSLAY HOSE BEDS Bidder Complies: Yes ( ) No ( )
Two (2) crosslays with 1.50" outlets shall be provided. Each bed to be capable of carrying single stack
200' of 1.75" hose double jacketed hose and shall be plumbed with 2.00" i.d. schedule 10 304L welded
or formed stainless steel pipe and gated with a 2.00" quarter turn ball valve. Threaded pipe shall not
be acceptable. Crosslays shall be low mounted with the bottom of both crosslay trays for safe reloading
and deployment. The hosebeds shall be full width of the body compartments.
Outlets to be equipped with a 1.50" National Standard hose thread 90-degree swivel located in the
hose bed so that hose may be removed from either side of apparatus.
The crosslay controls shall be at the pump operator's panel.
A removable tray shall be provided for the crosslay hosebed. The crosslay tray shall be constructed of
black poly to provide a lightweight sturdy tray. Two (2) hand holes shall be in the floor and additional
hand holes shall be provided in the sides for easy removal and installation from the compartment. The
floor of the trays shall be perforated to allow for drainage and hose drying. Trays shall be held in place
by a mechanical spring loaded stainless steel latch that automatically deploys upon loading the trays to
hold the trays in place during transit.
CROSSLAY HOSE BED, 2.50" Bidder Complies: Yes ( ) No ( )
One (1) crosslay with a 2.50" outlet shall be provided. The bed to be capable of carrying 200' of 2.5"
hose of 2.5" hose and shall be plumbed with 2.50" i.d. schedule 10 304L welded or formed stainless
steel pipe and gated with a 2.50" quarter turn ball valve. Threaded pipe shall not be acceptable.
The outlet to be equipped with a 2.50" National Standard hose thread 90 degree swivel located above
the hose bed so that hose may be removed from either side of apparatus.
The crosslay shall be mounted low next to the 1.5" crosslays. The crosslay controls shall be at the
pump operator's panel.
A removable tray shall be provided for the crosslay hosebed. The crosslay tray shall be as wide as the
crosslay opening will allow and constructed of black poly to provide a lightweight sturdy tray. Two (2)
hand holes shall be in the floor and additional hand holes shall be provided in the sides for easy
removal and installation from the compartment. The floor of the trays shall be perforated to allow for