Specifications
74 of 104
FRONT BUMPER TURRET DISCHARGE and OUTLET Bidder Complies: Yes ( ) No ( )
There will be a Task Force Tips Tornado front bumper turret, model Y2-E84A, piped to the passenger's
side of the front bumper extension. The monitor will be equipped with a disconnect to allow the
monitor to be easily removed to tilt the cab. NFPA Stacked tips, model FS-3STACK, and a model HMDC-
TO-ERP-1.5NH automatic nozzle will be provided.
The turret will have a horizontal rotation of 180 degrees and operate from 90 degrees above to 60
degrees below horizontal. The horizontal rotation and automatic oscillation will be driven by a 12 volt
DC direct drive motor/actuator.
The turret will be remotely controlled from a model Y4E-JS-GT joy stick control box located in the cab,
between the driver and passenger. The joy stick control box will have the capability to preset the
maximum valve position. A wireless remote operator station, model YE-RF-900, will also be provided. A
position indicator, TFT model Y4E-Disp, will be provided in the cab.
Plumbing will consist of a 2.00" valve with 2.50" piping and flexible hose according to the design
requirements of the chassis.
The 2.00" valve will operate with the turret joystick in the cab, or the wireless remote any time either
switch is activated. This valve will be installed in the pumphouse to prevent the outlet line from
freezing.
Automatic drains will be provided at all low points of piping.
DISCHARGE OUTLET (Front) Bidder Complies: Yes ( ) No ( )
There will be an additional 2.50" gated discharge outlet, with a swivel, piped to the driver's side next to
frame extension of the front bumper extension. Plumbing will consist of 2.50" piping from the pump
house. A 2.50" manually controlled full flow ball valve mounted in the pump house, controlled at the
pump operator’s panel, will be provided.
DISCHARGE OUTLET (Rear) Bidder Complies: Yes ( ) No ( )
There shall be one (1) discharge piped to the rear of the hose bed, on driver's side, installed so proper
clearance is provided for spanner wrenches or adapters. Plumbing shall consist of 2.50" piping along
with a 2.50" full flow ball valve with the control from the pump operator's panel. Discharge shall
terminate with 2.50" NST thread. Discharge piping shall be schedule 10 304L welded or formed
stainless steel and routed through the water tank.
DISCHARGE CAPS Bidder Complies: Yes ( ) No ( )
Chrome plated, rocker lug, caps with chains shall be furnished for all side discharge outlets.
The caps shall be the VLH, which incorporates an exclusive thread design to automatically relieve
stored pressure in the line when disconnected. (no exception)
OUTLET BLEEDER VALVE Bidder Complies: Yes ( ) No ( )
A .75" bleeder valve shall be provided for each outlet 1.50" or larger. Automatic drain valves are
acceptable with some outlets if deemed appropriate with the application.
The valves shall be located behind the panel with a swing style handle control extended to the outside
of the side pump panel. The handles shall be chrome plated and provide a visual indication of valve
position. The swing handle shall provide an ergonomic position for operating the valve without twisting
the wrist and provides excellent leverage. Bleeders shall be located at the bottom of the pump
panel. They shall be properly labeled identifying the discharge they are plumbed in to. The water
discharged by the bleeders shall be routed below the chassis frame rails.
ELBOWS, REAR OUTLETS Bidder Complies: Yes ( ) No ( )
The 2.50" discharge outlets, located at the rear of the apparatus, shall be furnished with a 2.50"(F)
National Standard hose thread x 2.50"(M) National Standard hose thread, chrome plated, 45 degree
elbow.