Specifications

73 of 104
The cap shall be the VLH, which incorporates an exclusive thread design to automatically relieve stored
pressure in the line when disconnected. (no exception)
CONTROL, REAR INLET Bidder Complies: Yes ( ) No ( )
The rear suction shall be gated with an electric operated control at the pump operator's panel. The
control shall be momentary to allow the valve to be gated for ease of operation. Indicator lights shall
be provided to show if the valve is open or closed.
INTAKE RELIEF VALVE Bidder Complies: Yes ( ) No ( )
An intake relief valve, preset at 125 psig, shall be installed on the inlet side of the valve.
Relief valve shall have a working range of 75 psig to 250 psig.
Outlet shall terminate below the framerails.
A .75" bleeder shall be provided.
INLET BLEEDER VALVE Bidder Complies: Yes ( ) No ( )
A .75" bleeder valve shall be provided for each side gated inlet. The valves shall be located behind the
panel with a swing style handle control extended to the outside of the panel. The handles shall be
chrome plated and provide a visual indication of valve position. The swing handle shall provide an
ergonomic position for operating the valve without twisting the wrist and provides excellent
leverage. The water discharged by the bleeders shall be routed below the chassis frame rails.
TANK TO PUMP Bidder Complies: Yes ( ) No ( )
The tank to pump line shall have a 3.00" Akron 8800 series full flow ball valve with "R-1" style
handle. This valve shall be controlled by an air actuated cylinder. The cylinder shall be large enough
to assure positive opening and closing of the valve. The red rocker switch controls shall be located on
the left pump operator's panel, be properly labeled as it's function and feature "green" valve open and
"red" valve closed indicator lights.
A 3.00" one-way full flow check valve shall be provided in the tank suction line to prevent back flow to
the tank.
TANK REFILL Bidder Complies: Yes ( ) No ( )
A 2.00" combination tank refill and pump re-circulation line shall be provided, using a quarter-turn full
flow ball valve controlled from the pump operator's panel.
DISCHARGE OUTLETS (Left Side) Bidder Complies: Yes ( ) No ( )
There shall be two (2) discharges with a 2.50" valves on the left side of the apparatus, terminating
with a male 2.50" National Standard hose thread adapter. Discharges shall be located below the cab,
and shall be no higher than the top of the chassis frame rail. Discharges shall not be located on the
pump operator's panel. Lever controls shall be provided at the valve.
DISCHARGE OUTLETS (Right Side) Bidder Complies: Yes ( ) No ( )
There shall be one (1) discharge with a 2.50" valve on the right side of the apparatus, terminating with
a male 2.50" National Standard hose thread adapter. The discharge shall be located below the crew
cab, and shall be no higher than the top of the chassis frame rail. The discharge shall be electrically
controlled at the pump operator's panel.
DISCHARGE OUTLET, 4.00" Bidder Complies: Yes ( ) No ( )
There shall be a 4.00" discharge outlet with a 4.00" Akron valve body installed on the right side of the
apparatus, below the cab, and shall be no higher than the top of the chassis frame rail, terminating
with a male 4.00" National Standard hose thread. This discharge outlet shall be electrically controlled
at the pump operator's control panel.