Specifications
61 of 104
The location shall be One in R1 to be 4" short of the door. Three in D1 two high and one low. One in
D3 upper behind the bulkhead. One in P1 as high as possible.
PULL-OUT TRAY Bidder Complies: Yes ( ) No ( )
There shall be one (1) slide-out tray, with 2" sides, and a capacity of 500 pounds provided. Capacity
rating shall be in the extended position.
The tray shall be constructed of .19" aluminum.
Slides (a minimum of two per tray) shall be an undermount-roller bearing type rated at 500lbs per pair
with a factor of safety of 2.
To ensure years of dependable service the slides shall be coated with a finish that is tested to
withstand a minimum of 1,000 hours of salt spray per ASTM B117.
To ensure years of easy operation, the slides shall require no more than a 50 pound force for push-in
or pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker)
test under full load. The vibration drive file shall have been generated from accelerometer data
collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition. Proof of
compliance shall be provided upon request.
Automatic locks shall be provided for both the "in" and "out" positions. The trip mechanism for it shall
be located at the front of the tray for ease of use with a gloved hand.
The tray shall be painted to match the compartment interior.
Tray location shall be rear portion of P3.
A heavy-duty assembly shall support the body under the compartment floor. It shall be attached to the
chassis frame for load transfer and to reduce stress on body.
PULL-OUT TRAY Bidder Complies: Yes ( ) No ( )
There shall be one (1) slide-out tray, without sides, and a capacity of 500 pounds provided. Capacity
rating shall be in the extended position.
The tray shall be constructed of .19" aluminum. The tray shall be painted to match the compartment
interior.
Slides (a minimum of two per tray) shall be an undermount-roller bearing type rated at 500lbs per pair
with a factor of safety of 2.
To ensure years of dependable service the slides shall be coated with a finish that is tested to
withstand a minimum of 1,000 hours of salt spray per ASTM B117.
To ensure years of easy operation, the slides shall require no more than a 50 pound force for push-in
or pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker)
test under full load. The vibration drive file shall have been generated from accelerometer data
collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition. Proof of
compliance shall be provided upon request.
Automatic locks shall be provided for both the "in" and "out" positions. The trip mechanism for it shall
be located at the front of the tray for ease of use with a gloved hand.
Tray location shall be installed in R1.
A heavy-duty assembly shall support the body under the compartment floor. It shall be attached to the
chassis frame for load transfer and to reduce stress on body.