Specifications

52 of 104
The light(s) selected above shall be controlled by the following:
A switch at the driver's side switch panel
These light(s) may be load managed when the parking brake is set
12 VOLT LIGHTING Bidder Complies: Yes ( ) No ( )
There shall be three (3) Whelen Model PCP2, 12 volt LED combination spotlight and floodlight(s)
installed in semi-recessed housing(s) Model PBA203 located three driver's side, one side of light tower
enclosure, two side of body one front and one rear.
The light(s) selected above shall be controlled by the following:
A switch at the driver's side switch panel
These light(s) may be load managed when the parking brake is set
12 VOLT LIGHTING Bidder Complies: Yes ( ) No ( )
There shall be one (1) Whelen Model PCP2, 12 volt LED combination spotlight and floodlight(s)
installed in semi-recessed housing(s) Model PBA203 located rear of body above the hard suction
storage, driver's side.
The light(s) selected above shall be controlled by the following:
A switch at the driver's side switch panel
These light(s) may be load managed when the parking brake is set
WATER TANK Bidder Complies: Yes ( ) No ( )
Booster tank shall have a capacity of 1000 gallons and be constructed of UV stabilized ultra high impact
polypropylene plastic by a manufacturer with a minimum of 20 years experience building tanks, is ISO
9001:2000 certified in all its manufacturing facilities, and has over 50,000 tanks in service.
The booster tank shall be a form-fitting design that serves to keep the tank height as low as
possible. The tank shall be no wider than 39.00" at the base to allow for greater compartment depth
and no wider than 53.00" at the top.
Tank joints and seams shall be nitrogen welded inside and out.
Tank shall be baffled in accordance with NFPA Bulletin 1901 requirements.
Baffles shall have vent openings at both the top and bottom to permit movement of air and water
between compartments.
Longitudinal partitions shall be constructed of .38" polypropylene plastic and shall extend from the
bottom of the tank through the top cover to allow for positive welding.
Transverse partitions shall extend from 4.00" off the bottom of the tank to the underside of the top
cover.
All partitions shall interlock and shall be welded to the tank bottom and sides.
Tank top shall be constructed of .50" polypropylene. It shall be recessed .38" and shall be welded to
the tank sides and the longitudinal partitions.
Tank top shall be sufficiently supported to keep it rigid during fast filling conditions.
Construction shall include 2.00" polypropylene dowels spaced no more than 30.00" apart and welded to
the transverse partitions. Two (2) of the dowels shall be drilled and tapped (.50" diameter, 13.00"
deep) to accommodate lifting eyes.
A sump that is 8.00" long x 8.00" wide x 6.00" deep shall be provided at the bottom of the water tank.