IP67 rated enclosure (Totally protected against dust and also protected against the effect of temporary
immersion between 15 centimeters and one (1) meter)
Operating voltage from eight (8) volts to 16 volts DC
The main controller shall activate status indicators and audible alarms designed to provide warning of
problems before they become critical.
CIRCUIT PROTECTION AND CONTROL DIAGRAM Bidder Complies: Yes ( ) No ( )
Copies of all job-specific, computer network input and output (I/O) connections shall be provided with
each chassis. The sheets shall indicate the function of each module connection point, circuit protection
information (where applicable), wire numbers, wire colors and load management information.
ON-BOARD ADVANCED/VISUAL ELECTRICAL SYSTEM DIAGNOSTICS Bidder Complies:
Yes ( ) No ( )
The on-board information center shall include the following diagnostic information:
Text description of active warning or caution alarms
Simplified warning indicators
Amber caution light with intermittent alarm
Red warning light with steady tone alarm
All control system modules, with the exception of the main control module, shall contain on-board
visual diagnostic LEDs that assist in troubleshooting. The LEDs shall be enclosed within the sealed,
transparent module housing near the face of the module. One LED for each input or output shall be
provided and shall illuminate whenever the respective input or output is active. Color-coded labels
within the modules shall encompass the LEDs for ease of identification. The LED indicator lights shall
provide point of use information for reduced troubleshooting time without the need for an additional
computer.
ADVANCED DIAGNOSTICS Bidder Complies: Yes ( ) No ( )
An advanced, Windows-based, diagnostic software program shall be provided for this control
system. The software shall provide troubleshooting tools to service technicians equipped with an IBM
compatible computer.
The service and maintenance software shall be easy to understand and use and have the ability to view
system input/output (I/O) information.
INDICATOR LIGHT AND ALARM PROVE-OUT SYSTEM Bidder Complies: Yes ( ) No ( )
A system shall be provided which automatically tests basic indicator lights and alarms located on the
cab instrument panel.
VOLTAGE MONITOR SYSTEM Bidder Complies: Yes ( ) No ( )
A voltage monitoring system shall be provided to indicate the status of the battery system connected to
the vehicle's electrical load. The system shall provide visual and audible warning when the system
voltage is below or above optimum levels.
The alarm shall activate if the system falls below 11.8 volts DC for more than two (2) minutes.
DEDICATED RADIO EQUIPMENT CONNECTION POINTS Bidder Complies: Yes ( ) No ( )
There shall be three (3) studs provided in the primary power distribution center located in front of the
officer for two-way radio equipment.
The studs shall consist of the following:
12-volt 40-amp battery switched power