Specifications

35 of 104
Lt Tower Not Stowed (Light Tower Not Stowed)
Hatch Door Open
Fold Tank Not Stowed (Fold-A-Tank Not Stowed)
Aerial Not Stowed (Aerial Device Not Stowed)
Stabilizer Not Stowed
Steps Not Stowed
Handrail Not Stowed
Any other device that is opened, extended, or deployed that creates a hazard or is likely to cause major
damage to the apparatus if the apparatus is moved shall be displayed as a caution message after the
parking brake is disengaged.
SWITCH PANELS Bidder Complies: Yes ( ) No ( )
The emergency light switch panel shall have a master switch for ease of use plus individual switches
for selective control. Each switch panel shall contain eight (8) membrane-type switches each rated for
one million (1,000,000) cycles. Panels containing less than eight (8) switch assignments shall include
non-functioning black appliques. Documentation shall be provided by the manufacturer indicating the
rated cycle life of the switches. The switch panel(s) shall be located in the overhead position above the
windshield on the driver side overhead to allow for easy access.
The switches shall be membrane-type and also act as an integral indicator light. For quick, visual
indication the entire surface of the switch shall be illuminated white whenever backlighting is activated
and illuminated red whenever the switch is active. For ease of use, a two (2)-ply, scratch resistant
laser engraved Gravoply label indicating the use of each switch shall be placed in the center of the
switch. The label shall allow light to pass through the letters for ease of use in low light conditions.
WIPER CONTROL Bidder Complies: Yes ( ) No ( )
For simple operation and easy reach, the windshield wiper control shall be an integral part of the
directional light lever located on the steering column. The wiper control shall include high and low
wiper speed settings, a one (1)-speed intermittent wiper control and windshield washer switch. The
control shall have a "return to park" provision, which allows the wipers to return to the stored position
when the wipers are not in use.
SPARE CIRCUIT Bidder Complies: Yes ( ) No ( )
There shall be two (2) pair of wires, including a positive and a negative, installed on the apparatus.
The above wires shall have the following features:
The positive wire shall be connected from a switch located on the cab switch panel, through
a relay.
The negative wire shall be connected to ground.
Wires shall be protected to 15 amps at 12 volts DC.
Power and ground shall terminate officer's side dash.
Termination shall be with 15 amp, power point plug with rubber cover.
Wires shall be sized to 125% of the protection.
This circuit(s) may be load managed when the parking brake is set.
SPARE CIRCUIT Bidder Complies: Yes ( ) No ( )
There shall be one (1) pair of wires, including a positive and a negative, installed on the apparatus.