Specifications
23 of 104
ten (10) hours, and a two (2) ounce per square inch layer of frost/ice has been able to build up on the
exterior windshield. The defroster system shall meet or exceed SAE J382 minimum defrosting system
performance requirements.
CAB/CREW CAB HEATER Bidder Complies: Yes ( ) No ( )
Two (2) 36,702 BTU auxiliary heaters with 276 SCFM each unit of air flow shall be provided inside the
crew cab, one (1) in each outboard rear-facing seat riser. The heaters shall include high performance
dual scroll blowers one (1) for each unit. Outlets for the heaters shall be located below each rear-
facing seat riser and below the fronts of the driver and passenger seats, for efficient airflow. An
extruded aluminum plenum shall be incorporated in the cab structure that shall transfer heat to the
forward cab seating positions.
The heater-defroster and crew cab heaters shall be controlled by a single integral electronic control
panel. The heater control panel shall allow the driver to control heat flow to the front and rear
simultaneously. The control panel shall include variable adjustment for temperature and fan control,
and be conveniently located on the dash in clear view of the driver. The control panel shall include
highly visible, progressive LED indicators for both fan speed and temperature. For increased
convenience, an optional dual control for the passenger position shall also be available.
WINDOW DEFROST FANS Bidder Complies: Yes ( ) No ( )
There shall be two (2) 12 volt DC fans mounted on the ceiling of the crew cab, located install on the
headliner between the seats. Install in the round recess in the housing to position the fans farther
forward than normal.
GRAB HANDLE Bidder Complies: Yes ( ) No ( )
A black rubber covered grab handle shall be mounted on the door post of the driver side and
passenger cab door to assist in entering the cab. The grab handle shall be securely mounted to the
post area between the door and windshield.
A long rubber grab handle shall be mounted on the dash board in front of the officer.
ENGINE COMPARTMENT LIGHT Bidder Complies: Yes ( ) No ( )
An engine compartment light shall be installed under the engine hood, of which the switch is an
integral part. Light shall have a .125" diameter weep hole in its lens to prevent moisture retention.
ACCESS TO ENGINE DIPSTICKS Bidder Complies: Yes ( ) No ( )
For access to the engine oil and transmission fluid dipsticks, there shall be a door on the engine tunnel,
inside the crew cab. The door shall be on the rear wall of the engine tunnel, on the vertical
surface. The door shall be 17.75" wide x 12.75" high and be flush with the wall of the engine tunnel.
The engine oil dipstick shall allow for checking only. The transmission dipstick shall allow for both
checking and filling. An additional tube shall be provided for filling the engine oil.
The door shall have a rubber seal for thermal and acoustic insulation. One (1) flush latch shall be
provided on the access door.
MAP BOX Bidder Complies: Yes ( ) No ( )
A map box with nine (9) bins, open from the top, shall be installed in cab on top of the aluminum work
surface, 6" forward of the rear of the engine tunnel. The outer dimensions of the map box shall be
36.00" wide x 22.00" deep x 10.00" high. The box shall be separated into two (2) sections.
The rear section shall consist of three (3) equally sized bins, approximately 12.00" x 10.00" x 10.00".
The forward section shall be 23.38" wide x 12.00" deep x 10.00" high. This section shall be separated
into six (6) bins with dividers placed at the following intervals from passenger side to driver side, 1.75",
1.75", 3.75", 3.75", 5.75", and 5.75" all dimensions clear opening of the slot. Each of the forward bin
dividers shall have a 30 degree slant beginning approximately at 2.00" from center of the map box