POWER OUTLET STRIP Bidder Complies: Yes ( ) No ( )
A six (6) place power outlet strip shall be provided location to be determined. The outlet strip shall
contain 120 volt, 15 amp straight blade receptacles.
The power outlet shall be wired to the shoreline input.
One (1) receptacle shall be provided.
20 AMP RECEPTACLE Bidder Complies: Yes ( ) No ( )
Wired to the power supply shall be one (1) receptacle that are a 120 volt 20 amp three wire twist-lock
NEMA L5-20 type with weather resisting cover located in the front passenger's side compartment, front
wall.
AIR REEL FOR TOOLS Bidder Complies: Yes ( ) No ( )
A reel shall be provided for air tool operation.
The reel system shall be piped from the CAFS. Plumbing to the reel shall be accomplished with as few
air restrictions as possible. Each reel shall have a minimum of 150 feet of .38", inside dimension,
Goodyear "Insta-Grip", heavy-duty, blue, #9273 hose installed on it.
The reel shall be equipped with a 12-volt electric rewind motor operated by a push button rewind
switch. The switch shall be guarded to prevent accidental operation and installed at a height not to
exceed 72 inches above the operators standing position.
The exterior finish of the reel(s) shall be painted #269 gray from the reel manufacturer.
A Nylatron guide shall be provided to aid in the payout and loading of the reel. A ball stop shall be
provided on the end of the hose to prevent the hose end from being wound around the reel.
A label shall be provided in a readily visible location adjacent to the reel. The label shall indicate
whether the supply is for breathing or utility air, the operating pressure, total hose length and hose
size (inside dimension).
A total of one (1) reel shall be located install in the hatch above the front passenger's side
compartment with access inside the front passenger's side compartment with air shut off in the P3 on
the partition rear of the reel guide and the regulator rear of the shut off.
LOOSE EQUIPMENT Bidder Complies: Yes ( ) No ( )
The following equipment shall be furnished with the completed unit:
- One (1) bag of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as used
in the construction of the unit
NFPA REQUIRED LOOSE EQUIPMENT, PROVIDED BY FIRE DEPARTMENT
The following loose equipment as outlined in NFPA 1901, 2009 edition, section 5.8.2 and 5.8.3 shall be
provided by the fire department. All loose equipment shall be installed on the apparatus before placed
in emergency service, unless the fire department waives NFPA section 4.21.
800 ft (60 m) of 2.50" (65 mm) or larger fire hose.
400 ft (120 m) of 1.50" (38 mm), 1.75" (45 mm), or 2.00" (52 mm) fire hose.
One (1) handline nozzle, 200 gpm (750 L/min) minimum.
Two (2) handline nozzles, 95 gpm (360 L/min) minimum.
One (1) playpipe with shutoff and 1.00" (25 mm), 1.125" (29 mm), and 1.25" (32 mm) tips.
One (1) SCBA complying with NFPA 1981,
Standard on Open-Circuit Self-Contained Breathing
Apparatus for Fire and Emergency Services
, for each assigned seating position, but not fewer
than four (4), mounted in brackets fastened to the apparatus or stored in containers supplied
by the SCBA manufacturer.