Specifications
88 of 104
REAR ZONE LOWER LIGHTING Bidder Complies: Yes ( ) No ( )
Two (2) Whelen, Model M6*C LED flashing warning lights with bezels shall be located at the rear of the
apparatus.
The driver's side rear light to be red
The passenger's side rear light to be blue
Both lights shall include a lens that is clear.
Both lights shall be controlled by a lighted switch on the switch panel.
WARNING LIGHTS (Rear and Side upper zones) Bidder Complies: Yes ( ) No ( )
Four (4) Whelen, model M9*C LED flashing warning lights shall be provided at the rear of the
apparatus.
The side rear upper light on the driver's side to be red
The rear upper light on the driver's side to be blue
The rear upper light on the passenger's side to be red
The side rear upper light on the passenger's side to be red
These lights shall include a lens that is clear
One (1) switch located in the cab on the switch panel shall control these lights.
TRAFFIC DIRECTING LIGHT Bidder Complies: Yes ( ) No ( )
There shall be one (1) Whelen model TAL65 36.01" long x 2.84" high x 2.24" deep, amber LED traffic
directing light installed at the rear of the apparatus.
The Whelen model TACTLD1 control head shall be included with this installation.
The auxiliary warning mode shall be activated with the control head only.
This traffic directing light shall be recessed with a smooth aluminum trim plate at the rear of the
apparatus as high as practical. The trim plate shall match the chevron striping on the rear of the truck.
The traffic directing light control head shall be located in the driver side overhead switch panel in the
right panel position.
ELECTRICAL SYSTEM GENERAL DESIGN for ALTERNATING CURRENT Bidder Complies:
Yes ( ) No ( )
The following guidelines shall apply to the 120/240 VAC system installation:
General
Any fixed line voltage power source producing alternating current (ac) line voltage shall produce
electric power at 60 cycles plus or minus 5 cycles.
Except where superseded by the requirements of NFPA 1901, all components, equipment and
installation procedures shall conform to NFPA 70, National Electrical Code (herein referred to as the
NEC).
Line voltage electrical system equipment and materials included on the apparatus shall be listed and
installed in accordance with the manufacturer's instructions. All products shall be used only in the
manner for which they have been listed.
Grounding