Manual
Choosing a Site
Chooseasitewitharmbaseandasclose
tothewatersourceaspossiblewithcorrect
powersupply.Makesureyourpressure
systemisalwaysconnectedtoanadequate,
reliablesourceofcleanwater.
Housing your Davey Pressure System
Toprotectyourpressuresystemfromtheweather,
makesurethepumphouseisbothwaterproof,
frostfreeandhasadequateventilation.Thepump
shouldbehorizontallymountedonarmbase
allowingfordrainage,toavoiddamagetoooring
etc.,thatovertimemayoccurfromleakingpipe
jointsorpumpseals.Donotmountthepump
vertically.
Agoodqualitynon-returnvalvemustbe
installedinthepressurepumpoutletpipework
beforethehotwaterservice.Failuretoinstall
thisnon-returnvalvemayresultinpump
damage.Suchdamageisnotcoveredby
guarantee.
Connection of Mains Scheme or Town Water Supply to either Suction or
Discharge of Pumps & Pressure Systems
MostWaterSupplyAuthoritieshavestrictregulationsregardingdirect
connectionofpumpstomainswatersupplies.Inmostcasesanisolatingtank
isrequiredbetweenmainssupplyandpump.Daveyalsorecommendthis
method.Directlyappliedmainspressurecanexceedpumpoperatingpressure
anddamagepump.
Davey Products Pty Ltd can
not accept responsibility
for loss or damage
resulting from incorrect or
unauthorised installations.
WARNING: Some insects, such as small ants, nd electrical devices
attractive for various reasons. If your pump enclosure is susceptible
to insect infestation you should implement a suitable pest control plan.
Pipe Connections
ForbestperformanceuseP.V.C.orpolythenepipesatleastthesame
diameterasthepump’sinletanddeliveryoutletopenings.Largerdiameter
pipemaybeusedtominimiseresistancetoowwhenpumpinglonger
distances.
Useunionsatpipeconnectionstoenableeasyremovalandservicing.Use
sufcienttapetoensureairtightsealandhandtightenonly.Topreventstrain
onpumpthreadsalwayssupportheavyinletandoutletpipes.Ifthereisa
likelihoodthewatersupplymaycontain
solidparticlessuchaspiecesofplantor
vegetablematter,asuctionstrainershould
beinstalledbeforethepumptoavoid
blockingofthepump.Laysuctionpipeat
aconstantgradienttoavoidairpockets
whichmayreducepumpefciency.
Where to use Check Valves and Foot Valves
Installationswithasuctionliftover1mrequireagoodqualityfootvalveto
avoidlossofprime.Inthiscase,thepoppetvalveinsidethepumpshould
beremoved.Installationswithoodedsuctionrequireagatevalvesowater
supplycanbeturnedoffforpumpremovalandservicing.
Priortousingthispumpyoumustensurethat:
• Thepumpisinstalledinasafeanddryenvironment
• Thepumpenclosurehasadequatedrainageintheeventofleakage
• Anytransportplugsareremoved
• Thepipe-workiscorrectlysealedandsupported
• Thepumpisprimedcorrectly
• Thepowersupplyiscorrectlyconnected
• Allstepshavebeentakenforsafeoperation
Appropriatedetailsforalloftheseitemsarecontainedinthefollowing
InstallationandOperatingInstructions.Readtheseintheirentiretybefore
switchingonthispump.IfyouareuncertainastoanyoftheseInstallationand
OperatingInstructionspleasecontactyourDaveydealerortheappropriate
Daveyofceaslistedonthebackofthisdocument.
Congratulationsonyourpurchaseofahighquality,AustralianbuiltDaveypres-
suresystem.Allcomponentshavebeendesignedandmanufacturedtogive
troublefree,reliableoperation.
1. Pressuretank
2. Pressureswitch
3. Deliveryoutlet
4. Suction inlet
5. Pump body
6. Motor
7. Base
8. Primingplug
Connectionsizes:
Model Inlet Outlet
X50 1” 1”
X70 1
1
/
4
” 1”
X90 1
1
/
4
” 1”
Do not use pipe thread sealing compounds on any part of this pump.
ONLY use Teon sealing tape.
Before installing your new pump, please read all instructions carefully as fail-
ures caused by incorrect installation or operation are not covered by the guar-
antee. Your Dynajet® system is designed to handle clean water. It should not
be used for any other purpose without specic referral to Davey. The use of the
pump to handle ammable, corrosive and other materials of a hazardous nature
is specically excluded.
Priming and Operation
1.Removeprimingplugandll
pumpandsuctionline(onooded
suction,simplyopengatevalve
topump).Whenfull,
replaceprimingplug.
2.Ensureoutletnearesttopumpis
open.
3.Ensureallvalvesinsuctionlineare
openandswitchon.
4.Primeshouldestablishalmost
immediatelyandastrongow
ofwatershouldbe
evidentfromthe
outlet.Allowwaterto
owfor10-20seconds
toexpelairthenclose
outlet.
5.Ifnoowisevidentfromtap,
switchoffatpowerpointandrepeat
fromstep1ensuringthereisan
adequatesupplyofwateravailable
tothepump.
Power Connection
Connect lead to power supply designated on pump label, do not use
long extension leads as they cause substantial voltage drop, poor
pump performance and may cause motor overload.
NOTE: Suction leaks are the
largest cause of poor pump
performance and are difcult
to detect. Ensure all
connections are completely
sealed using thread tape only.
IMPORTANT
For Automatic Pressure Pumps Installed with a Mains Pressure Hot
Water System.
Abrasive Materials
The pumping of abrasive materials will cause damage to the
pressure system which will then not be covered by the guarantee.