VM Series Stainless Steel Vertical Multistage Pumps Installation and Operating Instructions 60Hz These Instructions must be delivered with the pump to the operator. WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or property damage.
General Safety Specifications Symbols used in the manual Applications Pumps for clear liquids, free of abrasives in residential, agricultural, industrial, and other applications. Operating Conditions • Temperate range: • Ambient temperature: • Suction head: Read this data sheet carefully before installing and starting your pump. Pay special attention to the points concerning the safety of the equipment.
Two standard cases for pump installations: 1. Pump in suction lift situation. 2. Pump installed with positive inlet. Motor specifications are typical and should be confirmed at time of order. Assembly for pumps supplied without motors fitted Some Davey VM series multistage pumps require special size motor bearings built into the motor which may not allow the use of standard flange mounted motors. Suction Lift: Pumps operate more efficiently with positive suction.
Dry-running protection To avoid accidental loss of prime of the pump, we recommend protecting it with a suitable device. Refer to the motor data plate for its electrical characteristics (frequency, voltage, nominal current). The three-phase and single phase dual voltage motors must be protected by a circuit-breaker or magnetic contactor with overload set to the current marked on the motor data plate. Provide a fused disconnecting or isolating switch, in compliance with local standards.
Trouble Shooting Switch the pump OFF before doing any work on it SYMPTOM CAUSE REMEDIES PUMP TURNS BUT NO a) The internal parts are a) DISCHARGE FLOW obstructed by foreign bodies b) Suction pipe obstructed b) c) Air leaks in via suction pipe c) d) The pump has lost its prime d) e) The suction lift is too high, e) this is generally accompanied by cavitation noise f) The pump turns the wrong way f) g) The supply voltage to the g) motor is too low h) No incomin
NOTES 6
DAVEY PRODUCT GUARANTEE FOR AUSTRALIA & NEW ZEALAND This Davey product is guaranteed to be free of material or manufacturing defects at the time of original purchase. Should any part fail as a result of such defects within twelve months of original purchase, the product will be repaired free of charge. TERMS AND CONDITIONS 1. This guarantee applies to all states and territories of Australia and New Zealand only and is subject to the provisions of the Trade Practices Act (Aust.