User Manual
5.2 Orientation of terminal box (see
FIG. 4)
If necessary, the orientation of the motor,
andwithitthatoftheterminalbox,canbe
changed.
- Removethemotorattachmentscrews
and turn the motor to the desired
position.
Take care not to damage the
casing gasket, and reinstall it
correctly.
The terminal box should not be
placed at 3 and 6 o’clock on an
cold water circuit.
5.3 Electrical connection
The electrical connect must be
madebyaqualiedelectrician
and comply with applicable local
standards.
Complete electrical information about the
circulator is given on the data plate.
Power supply network
Useathree-conductorcable(3x
1.5mm
2
) to connect mains power to the
corresponding terminals of the circulator;
phase (L), neutral (N), and earth ( ) (see
FIG.5).
The power cable must not touch
the pipe or the pump; make sure
that it is away from any moisture.
Check line protection and the mains
voltageandfrequency.Thecirculator
must be connected to the mains via a
switch with an opening distance, on
eachpole,ofatleast3mm.Themotors
of the circulator models SC & SB are
self protected by impedance, therefore
theydon’tneedexternalprotection.The
motors of the circulators SS need a
contactorwithoverloadtted.Thepower
outlet must have an earthing contact.
Aftermakingtheconnections,putthe
coverbackontheterminalbox.
6. STARTING UP
6.1 Filling, degassing
Never operate the circulator
WITHOUT WATER
- Open the valves on both sides of
thecirculatorandlltheinstallation
completely.
- Bleed the circuit at the high point.
- Bleed air from the circuit, by hand, by
unscrewingtheplug(seeFIG.6)afew
turns; close it when water runs out and
when there are no more air bubbles.
Risks of scald. Use a
screwdriver for unscrewing
the tap.
- Power up the motor to start the
circulator.
- Theowrateisadjustedbychanging
the speed of rotation of the motor using
the selector switch.
Risk of burning. In
operation, the motor casing
may be hotter than 100
o
C.
7. SERVICING
Thecirculatorneedsnospecialservicing
inoperation.Themotorbearingsare
lubricatedbytheliquidpumped.
Atthebeginningofeachheatingseason,
or after a prolonged shutdown, make sure
that the circulator turns freely.
8. OPERATING TROUBLE
Causes and remedies
Switch the circulator OFF
before doing any work on
it.
~ 6 ~ ~ 3 ~