User guide
4 Auxiliary Air Button 
The Air Button controls anauxiliary air blower. It is used to turn the blower on and off, and select 
different operating modes if a Spa Power Variable-Speed Blower (SPVSB) has been tted. 2 pushes 
(STD) or 4 pushes (SPVSB) of the air button cycles the blower as follows: Note:In some spas an 
additional jet pump or pool light etc may be tted instead of a standard air blower. 
 Standard Air Blower (STD) 
Push 1 - Blower ON 
Push 2 - Blower OFF 
 Spa Power Variable-Speed Blower (SPVSB) (if tted) 
Note: If left on, this accessory will automatically switch off after 20 minutes. If the heater 
element is on, switching on this accessory may cause the heater to loadshed and switch off.
This is to keep the total power load to a safe level. 
4.1 Adjustable Speed Mode (SPVSB only) 
If a Spa Power Variable-Speed Blower is tted, the spa user has the ability to adjust the blower speed to any desired setting. 
The Up and Down buttons are used to set the desired blower speed. Note: If the blower is in Full Speed or Oscillating modes 
then pushing the Up or Down button will put it into Adjustable Speed mode and then adjust the speed. 
Step 1)  Press Air Button twice to set Adjustable Speed Mode 
Step 2)  Press Up 
 to increase speed of blower 
Step 3)  Press Down  
 to decrease speed of blower 
Push 4 - Blower OFF (Default State) 
AIR 
No 
Light 
Push 1 - Blower ON (Full Speed) 
Push 2 - Blower ADJUSTABLE (Adjustable Speed) 
Push 3 - Blower OSCILLATING (Oscillating Speed) 
AIR 
Red 
Light 
Orange 
Light 
AIR 
AIR 
Green 
Light 
2 Temperature Control 
The Spa Power controller automatically controls the pump and heater to lter the water and maintain it 
at the desired temperature set by the user (see below). The user can leave the system to look after the 
spa and know it will be at the correct temperature when ever he or she wants to use it. 
2.1 Adjusting Set Temperature 
The Spa Power controller gives the user direct control of the pool temperature from the poolside 
control panel. Holding down the Up or Down button will adjust the temperature set point as shown on 
the digital readout. There is a slight delay before the buttons operate to reduce the risk of accidental 
adjustment. The pool temperature will be maintained very close to the set temperature. 
 UP  Increase the set temperature by 0.5
o
C per beep (Max = 41.5
o
C) 
 DOWN  Decrease the set temperature by 0.5
o
C per beep (Min = 10.0
o
C) 
Default Display 
The display normally shows the temperature set point, unless the optional in pool temperature sensor 
is tted in which case the sensed water temperature is displayed. In either case the temperature set 
point will be displayed while being adjusted as describe dabove. 
2.2 Non-Default Display Value 
The non-default display value (either sensed water temperature 
or temperature set point) can be checked if necessary by 
pressing the Up &Down buttons simultaneously. 
2.3 Heating Mode Selection (24hr circ pump not tted) 
In addition to the temperature setting the user can select the preferred heating mode. The two 
available heating modesare... 
1. Demand Heating (displayed as Ht.d).This is the default setting in which the pump and heater will 
come on automaticallywheneverthetemperaturedropsslightlybelowthesetpoint. 
2. FiltrationOnlyHeating(displayedasHt.F).In this mode the pump and heater will come on 
automatically no more than once per hour to lter and heat the water. This mode is provided as an 
option for those who prefer to limit the natural cycling of the system. 
To select the heating mode rst press the Pump and Down buttons simultaneously to display the 
current heating 
mode, then press and hold the Up or Down buttons to change modes. 
AIR 
Light turns 
to orange
Page 8 Page 5