5 Light Operation 
Your spa may have been tted with either of two different LED lights; a Spa Power Coloured Light 
(SPCL) or a Spa Power Variable Coloured Light (SPVCL). The Spa Power Coloured Light is a single 
coloured light that is either on or off. The Spa Power Variable Coloured light is a light that has the 
ability to change between 12 different colours and white (see below for user instructions). 
The multi-function Light Button 
 is used to turn the light on and off (SPCL) and select through 
the different operating modes of the Spa Power Variable Colour Light. Two short presses of the button 
will turn the Spa Power Coloured Light on and off or ve short presses of the button will cycle the Spa 
PowerVariableColouredLight asfollows: 
 Light Button 
Push 1 - Light ON  (SPCL - On) (SPVCL Colour - White) 
Push 2 - Light ADJUST  (SPCL - Off) (SPVCL Adjustable Colour Mode) 
Push 3 - Light CYCLE SLOW  (SPVCL Cycle through colours - slowly)
Push 4 - Light CYCLE FAST  (SPVCL Cycle through colours - quickly) 
Push 5 - Light OFF  (Default State) 
Note: This is a multi-function button which performs the following - 
1) Short presses of this button activate the light functions as detailed above. 
2) Holding this button will begin to increase the set temperature of the spa. 
3) When a Spa Power Variable Speed Blower is tted and is turned on this button increases the  
blowerspeed. 
5.1 Adjustable Colour Mode (SPVCL only) 
When the light is on, short presses of the Down button   will put the light into adjustable colour 
mode and then sequentially select through all the available colours. The last colour set in this mode 
will be remembered the next time the light is used. 
5.2 Indicator Light 
A small red dot in the bottom corner of the digital readout indicates when the light is turned on. If left 
on the light will automatically switch off after 30 minutes. 
ON 
   Auto LED (No 24hr circulation pump tted) 
   The yellow Auto indicator light will appear on the touch pad whenever the system is in full 
automatic control mode. In this mode the system automatically activates the pump and heater 
to lter the water and maintain the set water temperature. If this light is ashing the water 
sensor is not detectinganywater. 
   H20 LED (24hr circulation pump tted) 
   Theyellow H20lightindicatesifwaterispresentintheheater.IfnowaterisdetectedthentheLED will 
ash and the unit will not operate except to run the circulation pump to try to get water to 
the heater. If no water reaches the heater for one minute then an H20 error will occur. If this 
happens thenpushingthepumpbuttonwillrunthecirculationpumpforanotherminute. 
   Pump LED 
   The green Pump indicator light will appear on the touch pad whenever the pump is running, in 
both autoandmanualusemode.Ifthislightisashing,thespaisinSleepMode. 
   Heat LED 
   The red Heater indicator light will appear on the touchpad whenever the heater element is on, 
in both auto and manual use mode. For safety the heater is always automatically controlled. 
Usuallyswitchingontheairbloweraccessorywillcausetheheater to switch off (loadshedding). This 
is in order to keep the total power load to a safe level. If this light is ashing the system has an 
error (see section 8). 
   Aux/Air LED 
   The Aux/Air indicator LED will appear on the touchpad whenever the Aux/Air button is pushed 
and conversly will disapear when the button is pushed again. Note: If the spa does not have a 
load connected to the controller the LED will still operate as described above. 
1 Touch Pads 