Manual

Congratulations onchoosingSpa-Quip’stopofthelineSpaPowercontrolsystem.
Page1
1.1BasicOperation
TheSP1200touchpadfeaturesalargedisplayconsistingoffournumericaldigitsand . Thedisplay
typicallyshowsthreequantities-Currentpooltemperature, and
Bydefaultthecurrentpooltemperatureisdisplayedonthenumericaldigitsleavingtheclockandset
temperatureonthetwolinesoftext. Thisconfigurationmaybechangedbytheuserifadifferentlayoutispreferred.
Wheneveratouchpadbuttonispressedthetwolinesoftextwilltemporarilydescribethenewlyselectedstate.
Likewisewhenthecontrollerisbusyperformingatask,textwillbedisplayedtoexplainwhatishappening(examples
includesleeping,purgingpumpsandwaterpriming).Eachofthesemessagesandtheassociatedfunctionis
describedinthefollowingsections.
twolinesoftext
Set(Target)pooltemperatureclock(weekdayand
time).
Thiscontrolleroffersalargerangeofpossibleaccessories,auserfriendlytouchpadandsuperiorcomponents.It
makesuseofthelatestelectronics,displayandsensortechnologytoprovideyouwiththemostsophisticated
controllerinitsclass.
1Introduction
36.75
Mon,
12:00
PM
C
Settemp
37.00
O
LightEffectMode
Pump1A
Pump1B
Aux
LightLevel
VariableSpeedBlower
Pump2A
Pump2B
AutoLED/WaterLED
HeaterLED
OzoneLED
SleepLED
Down Up
Scroll
1.2SP1200Touchpad
(SPVSB)
Page32
WheninanerrorstatethealarmcanbesilencedbypressingtheSCROLL button. Thealarmwill
automaticallysilenceafterfourminutes.
Error1(“PRIMEFAILED”)WaterPrimeFailed
Primefailedisaspecialcase. ThisisnotnecessarilyaproblemwiththeSP1200itself,butindicatesthatno
waterisbeingdetectedintheheaterhousing.OnapushoftheDOWNbuttonthemainpumpwillrunfor10
secondstotrytogetwatertotheheater.Ifsuccessfulnormaloperationwillresume.Ifunsuccessful,the
errorwillbeindicatedonthedisplayagain.Note:Whenthiserroroccursyouwillalsobegiventheoptionto
runtheSP1200indemomode,thisfeatureisnotintendedforendusers.Ifyouinadvertentlyenterdemo
mode,resetthespatostartover.
WithanyError3-8,spaoperationwillstopandnotcontinueuntilthecontrollerisreset.Thecontrollercan
onlyberesetbypushingtheLightLevel,LightEffectMode,Pump1AandPump2Abuttonssimultaneously.
The controller will remain in an error condition even when reset at mains power, controller will only continue
normal operation after the Light Level, Light Effect Mode, Pump 1A and Pump 2A buttons are pushed
simultaneously (see below).
Error4(“NOWATERSENSOR”)-NoWaterSensor
Thiserrorindicatesaproblemwiththeopticalwatersensorintheheater
. Theproblemmaybecausedbythe
sensorbeingdisconnectedorbydamagetothesensor. Trytoresetthespa.Ifthereisstillaproblemthen
contactyourspapoolsupplier.
Error3(“STUCKBUTTON”)-StuckButton
Thiserrorindicatesthatoneormoreofthetouchpadbuttonsisstuckorhasbeenhelddownformorethan
oneminute. Thismaybecausedbythepoolcoverpressingonthetouchpadorbywatergettingintothe
touchpadorbydamagetothetouchpaditself. Trytoresetthespa.Ifthereisstillaproblemthencontact
yourspapoolsupplier.
36.75
Mon,
12:00
PM
C
Settemp
37.00
O
TheSpaPower1200controllerhasextensiveselfdiagnosticcapabilities.Intheeventofa
problemitwillindicateawarningorerroraccordingtothenatureoftheproblem. Thespawill
continueoperatingifawarningisproducedbutuserinterventionorserviceisrequiredforerrors.
9Self-DiagnosticErrorCodes
Errors